2013
DOI: 10.1039/c2ay26138c
|View full text |Cite
|
Sign up to set email alerts
|

Validated voltammetric determination of olmesartan medoxomil: Method development and electrochemical behaviors investigation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 24 publications
0
4
0
Order By: Relevance
“…The plasma recovery ( Table 2 ) was found to be more than 85% for both of the drugs at different concentration levels suitable for bioanalytical analysis. Furthermore, the specificity and matrix effect of the formulation component were evaluated at three dose levels (1, 2, and 4 μ g/ml), employing a standard addition method [ 22 ]. The developed method is found to be specific for the coestimation of the PTX and DOX in the developed formulation system with matrix effect ≤ ±2% ( Figure 4(c) ).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The plasma recovery ( Table 2 ) was found to be more than 85% for both of the drugs at different concentration levels suitable for bioanalytical analysis. Furthermore, the specificity and matrix effect of the formulation component were evaluated at three dose levels (1, 2, and 4 μ g/ml), employing a standard addition method [ 22 ]. The developed method is found to be specific for the coestimation of the PTX and DOX in the developed formulation system with matrix effect ≤ ±2% ( Figure 4(c) ).…”
Section: Resultsmentioning
confidence: 99%
“…The developed formulation was lyophilized and further analyzed for specificity, matrix effect, entrapment, and loading efficiency utilizing the developed HPLC method [ 21 ]. To evaluate the matrix effect and specificity of the developed method, blank formulation was fortified with known amount of drug and dissolved in methanol to disrupt the nanocarrier [ 22 ]. The samples were then analyzed by the developed HPLC method for PTX and DOX in the presence of formulation components.…”
Section: Methodsmentioning
confidence: 99%
“…However, according to the literature, the reduction behavior of OM at PtIr-PEDOT/CFP can be attributed to saturation of the azomethine group C=N in tetrazolyl moiety of OM. 14 The plausible mechanism has been schematically represented in Figure 14.…”
Section: X-ray Photoelectron Spectroscopy (Xps)-mentioning
confidence: 99%
“…Electroanalytical methods offer advantages over other analytical methods in terms of simplicity, cost, rapid detection, requirement of sample in small quantity, non-requirement of derivatizations and less sensitivity toward matrix effects. [12][13][14][15] Surprisingly, there are only three reports based on electroanalytical methods for OM determination in bulk and dosage forms. These methods suffer from disadvantages like high detection limits, narrow linear dynamic range and complicated electrode preparation procedures.…”
mentioning