2010
DOI: 10.1016/j.talanta.2010.08.047
|View full text |Cite
|
Sign up to set email alerts
|

Validated liquid chromatographic-fluorescence method for the quantitation of gemifloxacin in human plasma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
29
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 35 publications
(29 citation statements)
references
References 13 publications
0
29
0
Order By: Relevance
“…Linear regression equation and correlation coefficient (R 2 ) were employed to statistically evaluate the linearity of the results (Ali et al, 2006;Lister, 2005;Al-Hadiya et al, 2010).…”
Section: Linearity and Rangementioning
confidence: 99%
See 1 more Smart Citation
“…Linear regression equation and correlation coefficient (R 2 ) were employed to statistically evaluate the linearity of the results (Ali et al, 2006;Lister, 2005;Al-Hadiya et al, 2010).…”
Section: Linearity and Rangementioning
confidence: 99%
“…To evaluate the specificity of the method, drug free lipid formulation (QC zero ) samples were carried out through the assay procedure and the retention times of the lipid formulation components were compared with those of ACV analyte (Al-Hadiya et al, 2010). In addition, specificity of the method toward the intact drug was also studied by determination of the resolution (R) between the drug peak and the nearest degradation product if present (Dongre et al, 2008).…”
Section: Specificitymentioning
confidence: 99%
“…1). Few analytical methods appeared in the literature for the determination of this drug including spectrophotometric [21][22][23][24], LC [25][26][27], HPLC [28,29], electrophoresis [30,31] and spectrofluorimetry [32,33] were reported for analysis of GFX.…”
Section: Introductionmentioning
confidence: 99%
“…Several methods have been reported for the determination of fluoroquinolones either in pure forms, in dosage forms, or in biological fluids like chromatography [3][4][5][6][7][8][9], capillary zone electrophoresis [10,11], electrochemistry [12][13][14][15], atomic absorption spectrometry [16,17], spectrofluorimetry [18][19][20][21] and spectrophotometric methods for GMF [22][23][24][25][26][27][28], MOX [16,[29][30][31][32][33] and GTF [16,[34][35][36][37][38][39][40][41][42][43][44]. These methods are associated with some major drawbacks such as decreased selectivity due to measurement in ultraviolet region [22,23,29,30] and/or de...…”
Section: Introductionmentioning
confidence: 99%