UV and VUV calibration capabilities at the Metrology Light Source for solar and atmospheric research

Abstract: A synchrotron-radiation-based variable angle ellipsometer for the visible to vacuum ultraviolet spectral range Review of Scientific Instruments 85, 055117 (2014) Abstract. The Physikalisch-Technische Bundesanstalt (PTB), Germany's national metrology institute, is responsible for the realization and dissemination of the legal units in Germany. Within this mission, PTB has been using synchrotron radiation for the realization of the radiometric units in the spectral range from the UV to the X-ray region for more … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 13 publications
0
5
0
Order By: Relevance
“…The direct, undispersed and calculable radiation of a MLS bending magnet is used at a so-called white-light beamline [18] for the direct calibration of energy-dispersive detectors or wavelength-dispersive or selective spectrometers [30] or for calibration of the source calibration transfer device. This transfer device consists of a mirror-monochromator-detector system that can be moved so as to be illuminated either by the calculable radiation of the MLS or by the source to be calibrated (figure 1(a)).…”
Section: Set-up and Calibration Principlementioning
confidence: 99%
See 2 more Smart Citations
“…The direct, undispersed and calculable radiation of a MLS bending magnet is used at a so-called white-light beamline [18] for the direct calibration of energy-dispersive detectors or wavelength-dispersive or selective spectrometers [30] or for calibration of the source calibration transfer device. This transfer device consists of a mirror-monochromator-detector system that can be moved so as to be illuminated either by the calculable radiation of the MLS or by the source to be calibrated (figure 1(a)).…”
Section: Set-up and Calibration Principlementioning
confidence: 99%
“…The newly set-up facility at the MLS for the calibration of radiation sources covers the spectral range from 7 nm to 400 nm [18,19].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The direct, undispersed, and calculable radiation of a MLS bending magnet is used at a so-called white-light beamline 23 for the calibration of the source calibration transfer device. This transfer device consists of a mirror-monochromatordetector system that can be moved so as to be illuminated either by the calculable radiation of the MLS or by the source to be calibrated (Fig.…”
Section: Principle Of Setupmentioning
confidence: 99%
“…collaborations, focusing on the calibration of space instruments [12,[20][21][22] and related transfer sources. In this paper, we focus on the spectral region from 116 nm to 400 nm, which is of scientific and also of industrial and commercial interest.…”
Section: Ptb's Radiometric Scales For Uv and Vuv Source Calibration B...mentioning
confidence: 99%