2016
DOI: 10.1253/circj.cj-15-0802
|View full text |Cite
|
Sign up to set email alerts
|

Utility of Real-Time 3-Dimensional Transesophageal Echocardiography in the Assessment of Mitral Paravalvular Leak

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0
1

Year Published

2016
2016
2018
2018

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 19 publications
(12 citation statements)
references
References 39 publications
(31 reference statements)
0
11
0
1
Order By: Relevance
“…17 Several studies have demonstrated the concordance between 3D-TEE images and the real anatomy, and the superiority of 3D-TEE over 2D-TEE in PVL evaluation. [18][19][20] To facilitate the communication between the interventionalist and echocardiographer, it is recommended that mitral PVL location be reported in a clockwise format from a surgeon's perspective or 'surgical view' (Fig. 2).…”
Section: Imaging In Transcatheter Paravalvularmentioning
confidence: 99%
See 2 more Smart Citations
“…17 Several studies have demonstrated the concordance between 3D-TEE images and the real anatomy, and the superiority of 3D-TEE over 2D-TEE in PVL evaluation. [18][19][20] To facilitate the communication between the interventionalist and echocardiographer, it is recommended that mitral PVL location be reported in a clockwise format from a surgeon's perspective or 'surgical view' (Fig. 2).…”
Section: Imaging In Transcatheter Paravalvularmentioning
confidence: 99%
“…22 3D-TEE also plays an important role in the selection of the most appropriate closure device (morphology and size) in each case. 20,23 For this purpose it is essential to perform a thorough characterization of the PVL (length, width, area) by direct planimetry using a 3D multiplanar reconstruction tool. 20 Fusion of different imaging modalities has gained increasing popularity over the last years.…”
Section: Imaging In Transcatheter Paravalvularmentioning
confidence: 99%
See 1 more Smart Citation
“…1). 3D-TEE is especially useful for mitral PVLs, being almost mandatory for a correct diagnosis [1517]. It is recommended that mitral PVL location be reported in a clockwise format from a surgeon’s perspective or ‘surgical view’ (Fig.…”
Section: Diagnosis Of Paravalvular Leakmentioning
confidence: 99%
“…Real-time 3D transesophageal echocardiography (TEE) with cardiac fluoroscopy X-ray imaging is well introduced into practice and is used to monitor and assist catheter-based cardiac operations [ 1 6 ].…”
Section: Introductionmentioning
confidence: 99%