Aims:The aim of this study was to assess the efficacy and safety of the Occlutech Paravalvular Leak Device (PLD) for the percutaneous closure of paravalvular leaks (PVL).Methods and results: Patients with PVL were enrolled at 21 sites from nine countries. Indications for PVL closure were heart failure and/or haemolytic anaemia. Endpoint measures were changes in PV regurgitation grade, NYHA class and requirement for haemolysis-related transfusion. One-hundred and thirty-six patients with mitral (67.6%) or aortic (32.4%) leaks were included (mean age 66.7 years, 58% male); 31% had multiple PVLs. The proportion of patients with NYHA Class III/IV decreased from 77.3% at baseline to 16.9% at latest follow-up. The proportion of patients with need for haemolysis-related blood transfusion decreased from 36.8% to 5.9% and from 8.3% to 0% for ML patients and AL patients, respectively. Allcause mortality was 7.4%. Complications included interference with valve leaflets (0.7%), transient device embolisation (percutaneously solved) (0.7%), late device embolisation (0.7%), recurrent haemolytic anaemia (2.2%), new-onset haemolytic anaemia (0.7%), valve surgery (2.2%), need for repeat closure (0.7%), complications at femoral puncture site (0.7%) and arrhythmias requiring treatment (4.4%).Conclusions: PVL closure with the Occlutech PLD demonstrated a high success rate associated with significant clinical improvement and a relatively low rate of serious complications.
IntroductionDue to the recent lack of definitions to establish the severity of paravalvular leak (PVL) and endpoints for its treatment, the effectiveness and safety of a new device for PVL closure have not been comprehensively analyzed.AimTo analyze a single center’s experience of mitral PVL closure in a surgical transapical catheter-based fashion with a purpose-specific device.Material and methodsThis is a retrospective cohort study of patients following transapical catheter-based mitral PVL closure with a purpose-specific device. Data were analyzed at baseline, perioperatively, at discharge, at six months and annually after the procedure.ResultsNineteen patients underwent surgical transapical catheter-based mitral PVL closure with the Occlutech PLD Occluder. Mean follow-up time was 20 ±7 (range: 9–33) months. The patients’ mean age was 64 ±7 years, and 11 (58%) were male. Technical, device and individual patient success at follow-up was achieved in 18 (95%), 16 (84%) and 16 (84%) patients respectively. Median intensive therapy unit stay was one day (1–4) and mean hospital stay was 11 ±4 days. A reduction of paravalvular regurgitation to a mild or lesser degree was achieved in 18 (95%) patients. There were no strokes or myocardial infarctions at follow-up. There were no deaths at 30 days after the procedure. One (5%) patient expired due to progression of heart failure 12 months after surgery. None of the patients required immediate conversion to full sternotomy.ConclusionsSurgical transapical catheter-based mitral PVL closure with the Occlutech PLD Occluder is a safe and clinically effective treatment.
Background: Recently extracorporeal membrane oxygenation is becoming the commonly used mechanical assist device for the treatment of severe cardiogenic shock in postcardiotomy patients. Evaluation of risk factors of negative outcome would be beneficial in decision-making in the elderly patient population. Methods: This was a retrospective single-centre analysis of elderly patients who underwent extracorporeal membrane oxygenation treatment for refractory cardiogenic shock in a tertiary care centre. Demographic data, comorbidities and perioperative parameters were collected to evaluate their impact on the outcome of extracorporeal membrane oxygenation treatment in this patient group. Logistic regression analysis of the variables was performed to identify factors predicting an adverse outcome. Results: Forty consecutive elderly patients underwent extracorporeal membrane oxygenation treatment during the study period. The mean age was 76.7 ± 3.8 years, 27 (68%) were male. The mean Survival after Veno–Arterial extracorporeal membrane oxygenation score before initiating extracorporeal membrane oxygenation support was − 11 ± 6. Intra-aortic counterpulsation was used as the first-line mechanical support in 31 (77%) patients. The mean duration of extracorporeal membrane oxygenation support was 172 ± 128 hours. Twenty-four patients (56%) were successfully weaned from extracorporeal membrane oxygenation, and 8 (20%) survived to hospital discharge. Lactate level before extracorporeal membrane oxygenation initiation was the only predictor of unfavourable outcome in multivariate analysis (p < 0.05). Conclusion: High lactate level before initiation of extracorporeal membrane oxygenation was the most important prognostic values of an unfavourable outcome.
Between December 2014 and March 2021, 144 patients with aortic (Ao) or mitral (Mi) paravalvular leaks (PVLs) were enrolled at 21 sites in 10 countries. Safety data were available for 137 patients, who were included in the safety analysis fraction (SAF), 93 patients with Mi PVLs and 44 patients with Ao PVLs. The full analysis set (FAS) comprised 112 patients with available stratum (aortic/mitral leak) as well as baseline (BL), 180-day or later assessments (2 years). Procedural success (implantation of the device with a proper closure of the PVL, defined as reduction in paravalvular regurgitation of ≥one grade as assessed by echocardiography post implantation) was achieved in 91.3% of FAS patients with Mi PVLs and in 90.0% of those with Ao PVLs. The proportion of patients suffering from significant or severe heart failure (HF), classified as New York Heart Association (NYHA) class III/IV, decreased from 80% at baseline to 14.1% at 2-year follow-up (FAS). The proportion of FAS patients needing hemolysis-related blood transfusion decreased from 35.5% to 3.8% and from 8.1% to 0% in Mi patients and Ao patients, respectively. In total, 35 serious adverse events (SAEs) were reported in 27 patients (19.7%) of the SAF population. The SAEs considered possibly or probably related to the device included device embolization (three patients), residual leak (two patients) and vascular complication (one patient). During follow-up, 12/137 (8.8%) patients died, but none of the deaths was considered to be device-related. Patients implanted with the Occlutech Paravalvular Leak Device (PLD) showed long-lasting improvements in clinical parameters, including NYHA class and a reduced dependency on hemolysis-related blood transfusions.
Myocardial fibrosis in aortic stenosis is associated with worse survival following aortic valve replacement. We assessed myocardial fibrosis in severe AS patients, integrating echocardiographic, cardiovascular magnetic resonance (CMR) and histological data. A total of 83 severe AS patients (age 66.4 ± 8.3, 42% male) who were scheduled for surgical AVR underwent CMR with late gadolinium enhancement and T1 mapping and global longitudinal strain analysis. Collagen volume fraction was measured in myocardial biopsies (71) that were sampled at the time of AVR. Results. CVF correlated with imaging and serum biomarkers of LV systolic dysfunction and left side chamber enlargement and was higher in the sub-endocardium compared with midmyocardium (p<0.001). CVF median values were higher in LGE-positive versus LGE-negative patients [28.7% (19-33) vs 20.7% (15-30), respectively, p=0.040]. GLS was associated with invasively (CVF; r=−0.303, p=0.013) and non-invasively (native T1; r=−0.321, p<0.05) measured myocardial fibrosis. GLS and native T1 correlated with parameters of adverse LV remodelling, systolic and diastolic dysfunction and serum biomarkers of heart failure and myocardial injury. Conclusion. Our data highlight the role of myocardial fibrosis in adverse cardiac remodelling in AS. GLS has potential as a surrogate marker of myocardial fibrosis, and high native T1 and low GLS values differentiated patients with more advanced cardiac remodelling.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.