2019
DOI: 10.1016/j.microc.2018.10.037
|View full text |Cite
|
Sign up to set email alerts
|

Utility of fluorescamine-based approach for highly sensitive spectrofluorimetric determination of Ceftazidime and Vancomycin in pharmaceuticals and real human plasma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
22
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 23 publications
(23 citation statements)
references
References 15 publications
1
22
0
Order By: Relevance
“…Each 0.5 ml of plasma was transferred to a centrifugation tube and spiked with various aliquots of the standard SPRC solution. Here, 1 ml acetonitrile was utilized as a protein precipitation agent, [17][18][19][20] the content was completed to 10 ml with distilled water and then centrifuged at 18 659 g for 10 min. The general analytical procedure was performed exactly as described in Section 2.4.…”
Section: Procedures For Detection Of Spec In Human Plasmamentioning
confidence: 99%
See 1 more Smart Citation
“…Each 0.5 ml of plasma was transferred to a centrifugation tube and spiked with various aliquots of the standard SPRC solution. Here, 1 ml acetonitrile was utilized as a protein precipitation agent, [17][18][19][20] the content was completed to 10 ml with distilled water and then centrifuged at 18 659 g for 10 min. The general analytical procedure was performed exactly as described in Section 2.4.…”
Section: Procedures For Detection Of Spec In Human Plasmamentioning
confidence: 99%
“…Stoichiometry between SPEC and NBD-Cl was checked using a continuous variation method (Job's method), [22] as described previously [20,23,24] by preparing 1 × 10 −4 M SPEC and NBD-Cl.…”
Section: Stoichiometry Mechanismmentioning
confidence: 99%
“…The amount of Pheo a conjugated to γ-PGA was determined by measuring the absorbance at 405 nm using an ultraviolet–visible (UV–visible) spectrometer. The amount of the targeting ligand EAE7 decorated onto HA was also measured using a fluorescamine assay [ 39 ].…”
Section: Methodsmentioning
confidence: 99%
“…According to the literature survey, some techniques were reported for the estimation of VANH in different matrices including spectrophotometric [4][5][6], spectro uorimetric [7][8][9], electrochemical [10][11][12], HPLC [13][14][15][16][17][18][19][20][21], LC-MS/MS [22][23][24][25][26][27][28][29][30][31][32][33], capillary electrophoresis [34][35][36][37], radioimmunoassay and ELISA-based immunoassay techniques [38][39][40]. VANH has native uorescence at 335 nm after excitation at 268 nm according to this study [8].…”
Section: Introductionmentioning
confidence: 99%