2017
DOI: 10.1016/j.vascn.2016.10.005
|View full text |Cite
|
Sign up to set email alerts
|

Using Tiletamine-Zolazepam-Xylazine Anesthesia Compared to CO 2 -inhalation for Terminal Clinical Chemistry, Hematology, and Coagulation Analysis in Mice

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 55 publications
0
8
0
Order By: Relevance
“…Briefly, mice were anesthetized with Zoletil 50 ® (30-50 mg/kg IP; Virbac, Co., Seoul, Korea) and Xylazine (5-10 mg/kg IP; Bayer Korea, Seoul, Korea) 24 h after the intranasal administration of LPS. The anesthetic conditions were based on previous studies (27,28), which provide information on the usefulness of the combined use of Zoletyl with Xylazine. This combined administration adequately maintained sedation and analgesia.…”
Section: Methodsmentioning
confidence: 99%
“…Briefly, mice were anesthetized with Zoletil 50 ® (30-50 mg/kg IP; Virbac, Co., Seoul, Korea) and Xylazine (5-10 mg/kg IP; Bayer Korea, Seoul, Korea) 24 h after the intranasal administration of LPS. The anesthetic conditions were based on previous studies (27,28), which provide information on the usefulness of the combined use of Zoletyl with Xylazine. This combined administration adequately maintained sedation and analgesia.…”
Section: Methodsmentioning
confidence: 99%
“…The intensity of the region of interest (ROI) was plotted in units of maximum number of photons per second per centimetres squared per steradian (p/sec/cm 2 /sr), ROIs were drawn over the signals and average radiant efficiency was quantified in terms of p/s/cm 2 /sr. All mice were sacrificed by CO 2 inhalation (flow rate, 20% CO 2 /min) (26) at 28 days after the start of tofacitinib treatment and tumours were removed.…”
Section: Methodsmentioning
confidence: 99%
“…In particular, due to differences in test chemistry (e.g., contact activators) and readout, reference ranges are machine-and reagent-specific and are not interchangeable [22]. In addition, variation in clotting parameters may be associated with the strain and/or sex of the animal, sampling technique, or type of anesthesia used [46,[49][50][51]. In our studies, values for strain 13/N guinea pigs did not significantly differ based on sex for any of the analytes.…”
Section: Discussionmentioning
confidence: 99%