2019
DOI: 10.1021/acsomega.9b02930
|View full text |Cite|
|
Sign up to set email alerts
|

Using Resonance-Enhanced Multiphoton Ionization Time-of-Flight Mass Spectrometry to Quantitatively Analyze the Creaming of an Emulsion

Abstract: In this study, we used a quantitative analytical method to indicate creaming behavior in an emulsion. An oil-in-water emulsion was directly measured by resonance-enhanced multiphoton ionization time-of-flight mass spectrometry, and the time profiles of the peak areas of an oil component, styrene, were obtained at heights of 1, 2, and 3 cm from the bottom of a sample that had a height of 4 cm. All time profiles roughly indicated that the signal intensity increased once, then decreased, and finally settled. More… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
1

Year Published

2020
2020
2021
2021

Publication Types

Select...
3

Relationship

3
0

Authors

Journals

citations
Cited by 3 publications
(8 citation statements)
references
References 30 publications
0
7
1
Order By: Relevance
“…The preparation procedure was similar to that in a previous report. 29 First, 0.12 g of SDS was dissolved in 40 mL of water in a 50-mL vial container. Next, either 44 or 176 μL of styrene, for emulsions with concentrations of either 1 or 4 g/L, respectively, was added, and processed in a homogenizer at 5000 rpm for 10 min.…”
Section: Reagents and Sample Preparationmentioning
confidence: 99%
See 3 more Smart Citations
“…The preparation procedure was similar to that in a previous report. 29 First, 0.12 g of SDS was dissolved in 40 mL of water in a 50-mL vial container. Next, either 44 or 176 μL of styrene, for emulsions with concentrations of either 1 or 4 g/L, respectively, was added, and processed in a homogenizer at 5000 rpm for 10 min.…”
Section: Reagents and Sample Preparationmentioning
confidence: 99%
“…Figure 1 shows the experimental apparatus. The REMPI-TOFMS used in the present study was similar to that used the previous study, 23,29 and is briefly described here. The fourth harmonic emission of a Nd:YAG laser (GAIA II, 266 nm, 4 ns, 10 Hz, Rayture Systems, Tokyo) was used as an ionization light source for REMPI.…”
Section: Rempi-tofmsmentioning
confidence: 99%
See 2 more Smart Citations
“…12 Moreover, they developed a new analytical tool, GC/MPI-TOFMS combined with a post-column on-line chemical reaction system for the trace analysis of nitro-PAHs in PM2.5. 13 Uchimura's group applied MPI-TOFMS to the direct analysis of emulsions; they have evaluated the creaming behaviors of emulsions 14,15 as well as a phase inversion by temperature changes. 16 Schade et al achieved the simultaneous detection of PAHs as well as positive and negative inorganic ions in singleparticle mass spectrometry.…”
mentioning
confidence: 99%