2017
DOI: 10.22179/revmacn.19.482
|View full text |Cite
|
Sign up to set email alerts
|

Use of UV-curable acrylates gels as mounting media for palynological samples

Abstract: UV-curable acrylates are used as an easy, economic and rapid mounting media to mount palynological samples. The aqueous palynological residue is dehydrated with ethanol in order to be set in UV-curable acrylates such as Trabasil ® NR2 and Acrysoft ® urethane acrylates. These mounting medias have advantages over other ones: specimens remain in fixed position, and/or they are not attacked by any organism or modified by any environmental conditions such as humidity and heat. In addition refraction index is simila… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0
1

Year Published

2019
2019
2022
2022

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 38 publications
(14 citation statements)
references
References 6 publications
0
10
0
1
Order By: Relevance
“…The organic residue was concentrated using standard methods with hydrochloric and hydrofluoric acids and sieved with a 20 µm filter. As mounting media of the palynological slides (at least five of each sample), it was followed the proposal of Noetinger et al (2017).…”
Section: Methodsmentioning
confidence: 99%
“…The organic residue was concentrated using standard methods with hydrochloric and hydrofluoric acids and sieved with a 20 µm filter. As mounting media of the palynological slides (at least five of each sample), it was followed the proposal of Noetinger et al (2017).…”
Section: Methodsmentioning
confidence: 99%
“…The sedimentary OM analysis was performed using a Rock-Eval 6 pyrolysis (Vinci Technology), available at the University of Lausanne, Switzerland, described in [59,60]. About 50-60 mg of sample powder was analyzed for each paleosols horizon and lacustrine deposit.…”
Section: Methodsmentioning
confidence: 99%
“…The method is based on the stepwise pyrolysis and combustion of OM, releasing CO and CO 2 gases monitored by a flame ionization detector (FID) for pyrolysis and an infrared detector (IR) for combustion under an artificial air supply (N 2 O 2 20/80). TOC content, Hydrogen Index (HI) and Oxygen Index (OI) were calculated by integrating the amounts of hydrocarbon compounds (HC), CO, and CO 2 produced during thermal cracking of OM and oxidative decomposition of carbonate, between defined temperature limits [59,60]. Although 69 bulk samples of the MAF were analyzed, two of them were dismissed because TOC values were extremely high (29.77 and 27.38%, respectively).…”
Section: Methodsmentioning
confidence: 99%
“…The spores were obtained mechanically removing sori with a dissection needle. For its observation with optic microscope, the material was mounted on a slide using Noetinger et al (2017) methodology. For observation under Scanning Electron Microscopy (SEM), the materials were mounted on an aluminum peg using adhesive film and coated with gold-palladium.…”
Section: Preparation Of Samples and Observationmentioning
confidence: 99%