2002
DOI: 10.2116/analsci.18.567
|View full text |Cite
|
Sign up to set email alerts
|

Use of Ring-Repeller, Double-Skimmer Electrodes for Efficient Ion Focusing in Mass Spectrometry

Abstract: The design and construction of a new type of time-of-flight mass spectrometer is described. The instrument was designed to improve the ionization efficiency and to efficiently detect ions. The system performance was evaluated using the SIMION software, and was compared with the experimental results. The shapes of the repeller, extraction, and ground electrodes had a strong effect on the trajectory of ions in the processes of ion acceleration and focusing. The major difference between the theory and the experim… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
8
0

Year Published

2002
2002
2016
2016

Publication Types

Select...
8

Relationship

5
3

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 11 publications
0
8
0
Order By: Relevance
“…The TOF-MS instrument developed in our laboratory has been described in detail elsewhere, [30][31][32][33] and is now commercially available (HGK-1, Hikari-GK, Fukuoka, Japan). One microliter of sample solution was injected into a GC (6890GC, Agilent Technologies) using an auto sampler (6890N, Agilent Technologies).…”
Section: Apparatusmentioning
confidence: 99%
“…The TOF-MS instrument developed in our laboratory has been described in detail elsewhere, [30][31][32][33] and is now commercially available (HGK-1, Hikari-GK, Fukuoka, Japan). One microliter of sample solution was injected into a GC (6890GC, Agilent Technologies) using an auto sampler (6890N, Agilent Technologies).…”
Section: Apparatusmentioning
confidence: 99%
“…The TOF-MS instrument used in this study was developed in our laboratory, [13][14][15] and is now commercially available (HGK-1, Hikari-GK, Fukuoka, Japan). For comparison of the techniques shown in Figs.…”
Section: Apparatusmentioning
confidence: 99%
“…This value is slightly superior to that obtained in previous experiments. 12 The diameters of the skimmers for the extraction and ground electrodes were expanded from 10 mm to 30 mm, and, as a result, the ions are not tightly focused and travel nearly in parallel in the flight tube. This is favorable for improving the mass resolution, since the difference in the distance that the ion travels to the detector can be minimal.…”
Section: Background Pressure and Signal Intensitymentioning
confidence: 99%
“…An assembly of electrodes for ion acceleration and focusing was designed for better ion transmission. 12 The configuration of the ion acceleration electrodes and the potentials applied to these electrodes were optimized. Figure 1 shows an experimental apparatus developed for use in this study.…”
mentioning
confidence: 99%
See 1 more Smart Citation