2014
DOI: 10.2116/analsci.30.445
|View full text |Cite
|
Sign up to set email alerts
|

Signal Enhancement by Crossing the Sample Flow at a Small Angle against the Laser Beam in Multiphoton Ionization Mass Spectrometry

Abstract: To enhance sensitivity in multiphoton ionization/time-of-flight mass spectrometry, the sample, in the form of an effusive molecular flow, was introduced at a small angle relative to the laser beam. This approach enlarged the volume of interaction between the sample and the laser beam, thus increasing the number of ions formed by multiphoton ionization. The sensitivity obtained using this technique was compared with that obtained using a previous method based on the off-axis sample introduction technique with d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 21 publications
0
5
0
Order By: Relevance
“…ΔEexcess, excess energy; M + , molecular ion: F + , fragment ion; F, neutral fragment; S0, ground state; S1, excited state (reproduced from ref. [22], with permission from the Royal Society of Chemistry). (reproduced from ref.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…ΔEexcess, excess energy; M + , molecular ion: F + , fragment ion; F, neutral fragment; S0, ground state; S1, excited state (reproduced from ref. [22], with permission from the Royal Society of Chemistry). (reproduced from ref.…”
Section: Discussionmentioning
confidence: 99%
“…The measured mass resolution was 1,600 [21]. The efficiency of ionization can be improved by 2.5 fold by introducing the molecular beam at the angle slightly off-axis with respect to the laser beam [22].…”
Section: Mass Spectrometermentioning
confidence: 97%
“…While these types of laser systems are still mostly found in research labs, user friendly short pulse fibre and disc laser systems are approaching similar specifications. 55 With further optimization of the laser-gas interaction geometry 56 which could include multiple reflections of the laser through the target, these detection sensitivities could be reached with current commercial lasers which are compact, rugged, and modestly priced.…”
Section: Discussionmentioning
confidence: 99%
“…The analytical instrument used in this study has been described in detail elsewhere [24,25]. Briefly, a GC (6890GC, Agilent technologies) equipped with an auto sampler (6890N, Agilent technologies) was combined with a TOF-MS developed in our laboratory and now commercially available (HGK-1, Hikari-GK, Fukuoka, Japan).…”
Section: Apparatusmentioning
confidence: 99%