2021
DOI: 10.1016/j.chroma.2021.462023
|View full text |Cite
|
Sign up to set email alerts
|

Femtosecond ionization mass spectrometry for chromatographic detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 50 publications
0
6
0
Order By: Relevance
“…Helium was used as a carrier gas at a flow rate of 1.0 mL min –1 . The analytes eluting from the column were measured by a linear-type TOFMS (mass resolution, m /Δ m = 1500) developed in this laboratory. , An assembly of microchannel plates (F4655-11, Hamamatsu Photonics, Shizuoka, Japan) was used as an ion detector. The temperature of a GC inlet as well as the interface between the GC and the MS was kept at 250 °C for a sample containing phenethylamine, 3,4-metylenedioxyphenethylamine, tryptamine, and nicotine, while the temperatures were decreased to 200 °C for a sample containing N -methylephedrine (and nicotine) to reduce thermal decomposition.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Helium was used as a carrier gas at a flow rate of 1.0 mL min –1 . The analytes eluting from the column were measured by a linear-type TOFMS (mass resolution, m /Δ m = 1500) developed in this laboratory. , An assembly of microchannel plates (F4655-11, Hamamatsu Photonics, Shizuoka, Japan) was used as an ion detector. The temperature of a GC inlet as well as the interface between the GC and the MS was kept at 250 °C for a sample containing phenethylamine, 3,4-metylenedioxyphenethylamine, tryptamine, and nicotine, while the temperatures were decreased to 200 °C for a sample containing N -methylephedrine (and nicotine) to reduce thermal decomposition.…”
Section: Methodsmentioning
confidence: 99%
“…Photoionization has been developed as a new technique for soft ionization in MS. , Photodissociation dynamics and ionization efficiency have been studied using a variety of pulse lasers as the ionization sources. A technique based on single photon nanosecond/femtosecond ionization is developed to enhance a molecular ion. , A hydrogen laser (ca. 8 eV) has been employed for this purpose .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…According to the physical and chemical properties of the analyte and the different internal energy transfer modes in the ionization process, different ionization methods can be used to ionize sample meteorological molecules into charged ions. Common ion sources include electron bombardment (EI) [243], chemical ionization (CI) [244], fast atom bombardment (FAB) [245], Matrix Assisted Laser Desorption Ion Sources (MALDI) [246], and Electrospray Ionization (ESI) [247].…”
Section: Mass Spectrometry (Ms)mentioning
confidence: 99%
“…Novel frequency doubling of the third harmonic of a Nd:YAG laser (177.3 nm) also holds the potential to be used in EGA–MS. Even femtosecond laser ionization was proposed for GCMS …”
Section: Laser-based Photoionizationmentioning
confidence: 99%