2009
DOI: 10.1002/jctb.2181
|View full text |Cite
|
Sign up to set email alerts
|

Use of PAT principles for the open‐loop control of laboratory and pilot‐scale chromatography columns

Abstract: BACKGROUND: Recently, there has been increased interest in employing process analytical technologies (PAT) that combine an understanding of how operating parameters affect product quality together with real-time analysis to achieve efficient process manipulation during operation and thereby ensure that product outputs meet specifications. Primarily intended as the basis of control strategies for full-scale manufacturing systems, such techniques can bring significant benefits for steps such as chromatographic s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2009
2009
2016
2016

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 19 publications
(16 reference statements)
0
4
0
Order By: Relevance
“…4,5 A stopped-flow analyzer has been used for at-line real-time measurement of product during HIC chromatography. 11 The at-line data such as the breakthrough curves shown in this paper gave the operator real-time confirmation that the process was proceeding according to plan. The at-line data also allowed for high resolution data to be collected, enhancing the characterization and development of the process.…”
Section: Process Chromatographymentioning
confidence: 64%
See 1 more Smart Citation
“…4,5 A stopped-flow analyzer has been used for at-line real-time measurement of product during HIC chromatography. 11 The at-line data such as the breakthrough curves shown in this paper gave the operator real-time confirmation that the process was proceeding according to plan. The at-line data also allowed for high resolution data to be collected, enhancing the characterization and development of the process.…”
Section: Process Chromatographymentioning
confidence: 64%
“…A stopped‐flow analyzer has been used for at‐line real‐time measurement of product during HIC chromatography . The at‐line data such as the breakthrough curves shown in this paper gave the operator real‐time confirmation that the process was proceeding according to plan.…”
Section: Recent Advances In Implementation Of Pat Towards Downstream mentioning
confidence: 97%
“…From a quality control perspective monitoring of critical quality attributes in the downstream stages are as important. Soft sensors could there play a profound role for improving process performance …”
Section: Discussionmentioning
confidence: 99%
“…Soft sensors could there play a profound role for improving process performance. 121 Consequently, further development of bioanalytical methods for on-line use would enhance the prospect for soft sensors in bio-therapeutic processes. A very interesting prospect for this is the miniaturisation and microfluidic approaches which have great potential for this.…”
Section: Discussionmentioning
confidence: 99%