2003
DOI: 10.1039/b301704d
|View full text |Cite
|
Sign up to set email alerts
|

Use of optional gas and collision cell for enhanced sensitivity of the organophosphorus pesticides by GC-ICP-MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
51
0
1

Year Published

2005
2005
2016
2016

Publication Types

Select...
4
4

Relationship

1
7

Authors

Journals

citations
Cited by 45 publications
(53 citation statements)
references
References 25 publications
(33 reference statements)
1
51
0
1
Order By: Relevance
“…OPPs are regarded as less persistent in the environment than organochlorine pesticides (OCPs) (Ferrando et al, 1992), and this family of chemicals is one of the substitutes for OCPs, which was banned for use in the 1970s (Vonderheide et al, 2003). It is well known that OPPs have genotoxicity (Cakir and Sarikaya, 2005), cytotoxicity (Giordano et al, 2007), reproductive toxicity (Pina-Guzman et al, 2005), and irreversible inhibitory activity to acetylcholinesterase (Jauregui et al, 2003).…”
Section: Introductionmentioning
confidence: 99%
“…OPPs are regarded as less persistent in the environment than organochlorine pesticides (OCPs) (Ferrando et al, 1992), and this family of chemicals is one of the substitutes for OCPs, which was banned for use in the 1970s (Vonderheide et al, 2003). It is well known that OPPs have genotoxicity (Cakir and Sarikaya, 2005), cytotoxicity (Giordano et al, 2007), reproductive toxicity (Pina-Guzman et al, 2005), and irreversible inhibitory activity to acetylcholinesterase (Jauregui et al, 2003).…”
Section: Introductionmentioning
confidence: 99%
“…Element specific detection of 31 P with ICP-MS was used for the determination of these phosphorus-containing pesticides. The difficulties of detecting phosphorus at trace levels by ICP-MS are already known and are related to the high ionization potential of this element and hence low ionization efficiency in an argon-sustained plasma [29,30] ) can interfere at m/z 31, especially when a regular quadrupole (with low mass resolution) is used. Despite these limitations the successful use of a quadrupole ICP-MS system for phosphorus determination has been reported [31].…”
Section: Study Of the Icp-ms Conditions For Pesticide Detectionmentioning
confidence: 99%
“…Historically, phosphorus has been recognized as one of the elements difficult to analyze in argon plasma. This is due to poor ionization because of its relatively high first ionization potential and because of isobaric interferences such as 15 [24]. However, proper optimization of ICP-MS parameters and high-resolution MS or collision/reaction cells are ways polyatomic interferences can be minimized or eliminated.…”
Section: Introductionmentioning
confidence: 98%