2020
DOI: 10.1016/j.ijcard.2020.08.016
|View full text |Cite
|
Sign up to set email alerts
|

Use of enhanced stent visualisation compared to angiography alone to guide percutaneous coronary intervention

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

7
11
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(18 citation statements)
references
References 22 publications
7
11
0
Order By: Relevance
“…Besides its positive contributions, ESI related uoroscopy time and radiation exposure can be expected to be higher than standard PCI, but the ouroscopy time and radiation exposure of ESI-guided coronary procedures are comparable to that of conventional angiography-guided PCI (22,23). In our study, uoroscopy time and radiation exposure dose were compatible to the studies in literature (22,23).…”
Section: Discussionsupporting
confidence: 86%
See 2 more Smart Citations
“…Besides its positive contributions, ESI related uoroscopy time and radiation exposure can be expected to be higher than standard PCI, but the ouroscopy time and radiation exposure of ESI-guided coronary procedures are comparable to that of conventional angiography-guided PCI (22,23). In our study, uoroscopy time and radiation exposure dose were compatible to the studies in literature (22,23).…”
Section: Discussionsupporting
confidence: 86%
“…In addition, this new innovative technology promises a practical and cost-effective clinical use. Emerging clinical studies investigating the impact of ESI to cardiology practice revealed that, ESI guided PCI is associated with lower rates of stent restenosis, target lesion revascularization in follow-up term and major adverse cardiovascular events compared with no use of ESI (21,22). Our study demonstrated that enhanced visualization of deployed coronary stent was associated with better post-interventional result measured as MLD.…”
Section: Discussionmentioning
confidence: 49%
See 1 more Smart Citation
“…In addition, ESV system was proved an effective assistance in reducing the excessive overlap in implantation of bioresorbable vascular scaffold (14). Furthermore, the results in the study of McBeath et al (16) showing a signi cantly improved correlations of an ESV system and clinical outcome. Jin et al (19) pointed out that the use of an ESV system (Stentboost, Philips) can be performed with comparable radiation dose with conventional x-ray uoroscopy imaging and suggested that the operator's experience have an important impact on radiation dose.…”
Section: Discussionmentioning
confidence: 98%
“…Therefore, how to reduce the need for contrast media and radiation exposure while ensuring surgical safety and image quality is critical at procedure of PCI Recently, an enhanced stent visualization (ESV) system (CLEARstent and CLEARstent Live; Siemens Healthineers, Germany) has been developed and deployed, providing a clear display of stent deployment by fade in/ fade out imaging (CLEARstent) and real time stent enhancement (CLEARstent Live). Several studies have demonstrated the feasibility, utility and e cacy of this system in facilitating PCI procedures and associating with better clinical outcomes (12)(13)(14)(15)(16). However, there is limited study on the contrast media usage with use of ESV technique during PCI for the patient with complication of CKD.…”
Section: Introductionmentioning
confidence: 99%