2022
DOI: 10.1016/j.talanta.2021.122881
|View full text |Cite
|
Sign up to set email alerts
|

Use of carbon black based electrode as sensor for solid-state electrochemical studies and voltammetric determination of solid residues of lead

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 50 publications
0
8
0
Order By: Relevance
“…Coated wire ion selective electrode (CW-ISE) [130], composite cork-graphite sensor (Figure 4) [131], disposable screen-printed non-single crystal silver electrode (AgSPE) [132], gold nanoparticle (AuNP)/hexaammineruthenium(III) ([Ru(NH3)6] 3+ )/Nafion modified GCE [133], and carbon blackmodified carbon paste (CB-CP) electrode [134], were fabricated and used as working electrodes in the determination of Pb 2+ in various commercial cosmetics. (2) 3.…”
Section: Heavy Metalsmentioning
confidence: 99%
“…Coated wire ion selective electrode (CW-ISE) [130], composite cork-graphite sensor (Figure 4) [131], disposable screen-printed non-single crystal silver electrode (AgSPE) [132], gold nanoparticle (AuNP)/hexaammineruthenium(III) ([Ru(NH3)6] 3+ )/Nafion modified GCE [133], and carbon blackmodified carbon paste (CB-CP) electrode [134], were fabricated and used as working electrodes in the determination of Pb 2+ in various commercial cosmetics. (2) 3.…”
Section: Heavy Metalsmentioning
confidence: 99%
“…Typically, the redox probe can either be free in the electrolyte solution or immobilized on the electrode surface. Amongst, electrochemical aptasensors based on the immobilization of redox probes on the electrode surface offer higher detection sensitivity ( Maciel et al, 2022 ). This is attributed to the tight immobilization of the electrochemical redox probe on the electrode surface, resulting in a shorter electron transfer pathway.…”
Section: Introductionmentioning
confidence: 99%
“…The nanomaterial is often employed as thin film or electrode coating in conjunction with other nanoparticles and active materials. Recently, few studies have proposed the use of CB-based sensors to enhance the sensitivity of electrochemical sensors for stripping voltammetric analysis [24][25][26][27][28]. However, few studies have been conducted for metal analysis.…”
Section: Introductionmentioning
confidence: 99%