2000
DOI: 10.1016/s1079-2104(00)70104-1
|View full text |Cite
|
Sign up to set email alerts
|

Updated quality assurance self-assessment exercise in intraoral and panoramic radiography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
6

Year Published

2004
2004
2021
2021

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(12 citation statements)
references
References 5 publications
0
6
0
6
Order By: Relevance
“…Early research indicates that the F‐speed films have a contrast equal to or greater than Ektaspeed Plus, with an exposure dose reduction of at least 20% . According to our survey, only 3.3% dentists reported that they used F‐speed film.…”
Section: Discussionmentioning
confidence: 63%
“…Early research indicates that the F‐speed films have a contrast equal to or greater than Ektaspeed Plus, with an exposure dose reduction of at least 20% . According to our survey, only 3.3% dentists reported that they used F‐speed film.…”
Section: Discussionmentioning
confidence: 63%
“…In dental radiology, quality control has been wrongly focused on only the control/development of equipment, such as the development of the X-ray apparatus and processors 3. However, another fundamental factor influencing the quality of dental radiology is the training that professionals who perform radiographs receive; this training must be maintained at a satisfactory level to ensure safety during examinations 4…”
Section: Introductionmentioning
confidence: 99%
“…Um benefício adicional da colimação retangular é uma melhoria no contraste radiográfico como resultado de uma redução no embaçamento causado pela radiação secundária e espalhada. 20 O feixe de raios X não deve exceder a cobertura mínima necessária, e cada dimensão do feixe deve ser colimada de forma que o feixe não exceda o receptor em mais de 2 por cento da distância do receptor da fonte para a imagem. 28 A área útil do filme radiográfico ou sensor digital PSP, de tamanho Nº2 é de 12cm2 .…”
Section: Colimaçãounclassified
“…Uma configuração acima de 90 kV (p) aumentará a dose do paciente e não deve ser usada. 20 O potencial operacional ideal das unidades de raios X dentais está entre 60 e 70 kVp. 28,20 As instalações devem se esforçar para definir o temporizador de exposição da unidade de raios-X para a configuração mais baixa, fornecendo uma imagem de qualidade diagnóstica.…”
Section: Potencial De Operação E Tempo De Exposiçãounclassified
See 1 more Smart Citation