1978
DOI: 10.1007/bf00491943
|View full text |Cite
|
Sign up to set email alerts
|

Untersuchung von systematischen Fehlern bei der Bestimmung von Hg-Gesamtgehalten im Bereich < 10−5% in anorganischen und organischen Matrices mit zwei unabhängigen Verbundverfahren

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
7
0
1

Year Published

1981
1981
2003
2003

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 55 publications
(9 citation statements)
references
References 67 publications
1
7
0
1
Order By: Relevance
“…When SnC12 is used as a reductant (in FIAS), it was observed that the efficiency of the cold vapour generation strongly depends on the type of acid present in the solution as well as on its concentration. This is in agreement with conclusions of Kaiser et al [6]. Therefore the influence of nitric acid, hydrochloric acid and a mixture of both acids on the absorbance was investigated for model solutions containing 20 gg/1 Hg(II).…”
Section: Cold Vapour Atomic Absorption Spectrometrysupporting
confidence: 77%
See 1 more Smart Citation
“…When SnC12 is used as a reductant (in FIAS), it was observed that the efficiency of the cold vapour generation strongly depends on the type of acid present in the solution as well as on its concentration. This is in agreement with conclusions of Kaiser et al [6]. Therefore the influence of nitric acid, hydrochloric acid and a mixture of both acids on the absorbance was investigated for model solutions containing 20 gg/1 Hg(II).…”
Section: Cold Vapour Atomic Absorption Spectrometrysupporting
confidence: 77%
“…As a reducing agent for CV AAS typically SnC12 is used [4]. Kaiser et al [6] compared tin(II) chloride and sodium tetrahydroborate(III) for reduction of organic and inorganic mercury in respect to their tolerance for other elements present in the sample solution. In our investigations, mercury was reduced by SnC1 e solution in the FIAS unit, while in FIMS mercury reduction was performed by NaBH 4 solution.…”
Section: Measurement Proceduresmentioning
confidence: 99%
“…Among the determination methods microwave-induced plasma optical emission spectrometry (MIP-OES)40 proved to be extremely sensitive and up to a large extend free of interferences. 41 By its high volatility, Hg already can be separated from inorganic or organic matrices during the intitial decomposition stage in a sealed system by means of oxygen excited in a microwave field, cf. Fig.…”
Section: Special Sectionmentioning
confidence: 99%
“…Die Nachweisgrenze der Bestimmung von Quecksilber im Urin kann gesenkt werden, wenn eine größere Menge Urin eingesetzt wird. Es ist jedoch darauf hinzuweisen, daß die Kontrolle der Kontaminationen, wenn kleinere Mengen als l Mg/1 nachgewiesen werden sollen, oft sehr schwierig und aufwendig ist (10 …”
Section: Einführungunclassified