2022
DOI: 10.3390/en15207608
|View full text |Cite
|
Sign up to set email alerts
|

Unipolar Arc Ignited Partial Discharge for 650-V AlGaN/GaN HEMTs during the DC Breakdown Voltage Measurement

Abstract: Without the Fluorinert solution and proper pad design, the high–voltage (HV) transistor used during the DC breakdown voltage (Vbk) measurement might be damaged by the partial discharge (PD) in the air if its Vbk is close to one thousand volts or more. From the waveform measurement, the PD in the air occurred at 650 V HV GaN HEMTs during the Vbk measurement, it is ignited by the unipolar arc, and it is not ignited by the avalanche breakdown. This is based on the fact that the current falls below zero ampere to … Show more