2001
DOI: 10.1016/s1044-0305(01)00246-x
|View full text |Cite
|
Sign up to set email alerts
|

Underwater mass spectrometers for in situ chemical analysis of the hydrosphere

Abstract: Underwater mass spectrometry systems can be used for direct in situ detection of volatile organic compounds and dissolved gases in oceans, lakes, rivers and waste-water streams. In this work we describe the design and operation of (1) a linear quadrupole mass filter and (2) a quadrupole ion trap mass spectrometer interfaced, in each case, with a membrane introduction/fluid control system and packaged for underwater operation. These mass spectrometry systems can operate autonomously, or under user control via a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
53
0

Year Published

2003
2003
2018
2018

Publication Types

Select...
5
5

Relationship

0
10

Authors

Journals

citations
Cited by 82 publications
(54 citation statements)
references
References 12 publications
(8 reference statements)
1
53
0
Order By: Relevance
“…In situ measurements of the methane flux from the sediment into the water column were performed with an underwater mass spectrometer (Bell et al, 2007(Bell et al, , 2011Gentz and Schlüter, 2012;Schlüter and Gentz, 2008;Short et al, 2001Short et al, , 2006Wenner et al, 2004). Fluxes were calculated on the basis of changes in gas concentrations within the chamber over time.…”
Section: Sampling Strategymentioning
confidence: 99%
“…In situ measurements of the methane flux from the sediment into the water column were performed with an underwater mass spectrometer (Bell et al, 2007(Bell et al, , 2011Gentz and Schlüter, 2012;Schlüter and Gentz, 2008;Short et al, 2001Short et al, , 2006Wenner et al, 2004). Fluxes were calculated on the basis of changes in gas concentrations within the chamber over time.…”
Section: Sampling Strategymentioning
confidence: 99%
“…Each 1.3 s a dataset is recorded. A detailed consideration of the Inspectr200-200 is given by Short et al [16,26] and about the gas permeation within the membrane inlet system by Bell et al [23].…”
Section: Underwater Mass Spectrometer: Inspectr200-200mentioning
confidence: 99%
“…Most of the oceanographic applications of this technique have, thus far, centered on measurements of the major dissolved gases (CO 2 , O 2 , N 2 , and Ar) in discrete samples from coastal waters and sediments (Kana et al 1998;Hartnett and Seitzinger 2003). Very little work has been done, however, on the shipboard underway measurement of trace gases (e.g., CH 4 , N 2 O, and DMS) in open ocean waters, though recent progress has been made toward in situ trace gas analysis in eutrophic waters (Short et al 2001).…”
mentioning