Dissolved gas measurements in oceanic waters made by membrane inlet mass spectrometry

Abstract: A method is presented for the shipboard analysis of dissolved gases (O 2 , CO 2 , Ar, N 2 , H 2 S, dimethylsulfide) in oceanic waters using membrane inlet mass spectrometry (MIMS). Gases are extracted from seawater across a semipermeable membrane into the ion source of the mass spectrometer. The method can be used to simultaneously measure both major and trace gases in seawater samples in near real-time. In the case of DMS, low nmol L -1 detection limits can be achieved without any concentration step. Multiple… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

5
150
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 159 publications
(160 citation statements)
references
References 37 publications
5
150
0
Order By: Relevance
“…After incubation, sediment and overlying water were homogenised and subsamples of the slurries were collected in 125 mL glass bottles, sealed with crimptop septa and poisoned using 0.5 mL of 50% ZnCl 2 solution. These sub-samples were stored in the dark at room-temperature until analysis by membrane inlet mass spectrometry (MIMS) (Tortell 2005). Analytical grade water (18.2 MX Millipore-MilliQ) and seawater (salinity 37) were equilibrated with air at 25°C and used as standards, given temperature and salinity dependence of O 2 solubility (Garcia and Gordon 1992).…”
Section: Incubation Experiments Bmentioning
confidence: 99%
“…After incubation, sediment and overlying water were homogenised and subsamples of the slurries were collected in 125 mL glass bottles, sealed with crimptop septa and poisoned using 0.5 mL of 50% ZnCl 2 solution. These sub-samples were stored in the dark at room-temperature until analysis by membrane inlet mass spectrometry (MIMS) (Tortell 2005). Analytical grade water (18.2 MX Millipore-MilliQ) and seawater (salinity 37) were equilibrated with air at 25°C and used as standards, given temperature and salinity dependence of O 2 solubility (Garcia and Gordon 1992).…”
Section: Incubation Experiments Bmentioning
confidence: 99%
“…derway measurements of salinity, temperature, and fluorescence by thermosalinograph fluorometry, pCO 2 by membrane inlet mass spectrometry (MIMS) (42), and phytoplankton cell abundances and cellular autofluorescence by a custom-built flow-through cytometer (SI Materials and Methods) (43 Hydrographical Data. In June 2008, discrete, size-fractioned chlorophyll a concentrations were determined by the in vitro fluorometry using the acidification method (45).…”
Section: Methodsmentioning
confidence: 99%
“…[8][9][10][11][12][13]), it is a rather new application in marine and limnic research. Studies by Tortell [14] of 02' DMS or N 2 concentrations in surface waters or by Hartnett and Seitzinger [15], investigating nitrogen concentrations in sediment cores, underlined the suitability of MIMS for geochemical investigations of marine and limnic environments.…”
mentioning
confidence: 99%
“…Whereas a few studies applied MIMS for analysis of CO 2 , O 2 , or DMS concentrations in marine environments, or considered relative shifts of peak intensities indicative for CH 4 concentrations [14,16,17], the calibration of an UWMS for measurement of methane concentration in coastal areas and lakes is a rather new topic. For this purpose, we applied the Inspectr200-200 (AML) underwater mass spectrometer.…”
mentioning
confidence: 99%