Understanding Dry Powder Inhalers: Key Technical and Patient Preference Attributes

Abstract: Inhalable medications for patients with asthma and chronic obstructive pulmonary disease (COPD) can be confusing even for health care professionals because of the multitude of available devices each with different operating principles. Dry powder inhalers (DPI) are a valuable option for almost all of the patients with asthma or COPD. Based on recorded patient inspiratory profiles, the peak inspiratory flow requirement of 30 L min−1 of high-resistance devices does not usually pose any practical limitations for … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
54
0
4

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 69 publications
(59 citation statements)
references
References 58 publications
1
54
0
4
Order By: Relevance
“…The mean PIF rates observed also reflect the relative inhaler airflow resistances: the highest mean PIF was achieved via the inhaler with the lowest resistance (the center slot 1198 Easyhaler [0.036 √kPa min/L]). 19 The consistency observed between our findings and those from elsewhere adds additional strength to the findings of this study. When using the Easyhaler, no patient with COPD or healthy volunteer failed to achieve the 30L/min PIF rate considered to be the minimum required to achieve delivery and deposition of aerosolized drug deep into the lungs.…”
Section: Discussionsupporting
confidence: 86%
“…The mean PIF rates observed also reflect the relative inhaler airflow resistances: the highest mean PIF was achieved via the inhaler with the lowest resistance (the center slot 1198 Easyhaler [0.036 √kPa min/L]). 19 The consistency observed between our findings and those from elsewhere adds additional strength to the findings of this study. When using the Easyhaler, no patient with COPD or healthy volunteer failed to achieve the 30L/min PIF rate considered to be the minimum required to achieve delivery and deposition of aerosolized drug deep into the lungs.…”
Section: Discussionsupporting
confidence: 86%
“…Again, this might be attributed to the improved flowability and further reduced particle aggregation. 48 , 49 PDI values remained below 0.5 while ZP values of 31.90 ± 1.697 and 31.20 ± 3.11 mV for the improved SD/P4 and SD/P6, respectively, ensured physical stability of the proliposomes similar to their old counterparts. % EE values were comparable with old formulations.…”
Section: Preparation and Characterization Of The Improved Spray-driedmentioning
confidence: 91%
“… 47 By referring to Table 1 , it is evident that formulations SD/P1, SD/P3, SD/P9, SD/P11, SD/P17 and SD/P19 prepared using lower amounts of the carrier (0.5 g) produced significantly (P < 0.05) larger PS values > 600 nm compared to their counterparts prepared using larger amounts of the carrier (1 g). This might be attributed to the increased particle aggregation and hence poor powder flowability with lower carrier amounts, 48 , 49 highlighting the importance of the added carrier.…”
Section: Particle Size (Ps) Polydispersity Index (Pdi) and Zeta Potementioning
confidence: 99%
See 1 more Smart Citation
“…Various devices can be used to administer OIDs to patients, including dry-powder inhalers (DPIs), pressurized metered-dose inhalers (pMDIs) and nebulizers. These devices have been extensively discussed in several recent works [18][19][20][21][22][23][24][25]. Briefly, DPIs deliver powder particles carrying the drug; pMDIs and nebulizers generate liquid droplets containing the drug.…”
Section: Inhalation Therapymentioning
confidence: 99%