Unbalanced Current Reduction Method of Microgrid Based on Power Conversion System Operation

Abstract: In isolated areas such as islands with small power grids, the BESS (Battery energy storage system) can supply the standard voltage and frequency to the power system to achieve 100% of renewable sharing. In addition, the installation of additional BESS may be required in the microgrid due to technical limitations such as redundant operation and manufacturer specifications. Thus, the BESSs in a microgrid can be split into main and sub BESSs which play a role as the main source and auxiliary services, respectivel… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 32 publications
0
3
0
Order By: Relevance
“…Furthermore, BESS's optimal planning and sizing for frequency control in power grids have been widely considered when penetrating renewable RESs and the grid [6]. Integrating the BESS into the microgrid can deliver main and auxiliary services for reliable and efficient power flow control [91]. In another study, ref.…”
Section: Besss For Power Smoothingmentioning
confidence: 99%
“…Furthermore, BESS's optimal planning and sizing for frequency control in power grids have been widely considered when penetrating renewable RESs and the grid [6]. Integrating the BESS into the microgrid can deliver main and auxiliary services for reliable and efficient power flow control [91]. In another study, ref.…”
Section: Besss For Power Smoothingmentioning
confidence: 99%
“…To calculate current references, any four out of six expressions ( 14)- (19), can be used. Still, the most meaningful sets of equations are ( 14)-( 17) and ( 14), ( 15), (18), and (19).…”
Section: Power and Current Production Maximization And Management Schemementioning
confidence: 99%
“…To calculate current references, any four out of six expressions ( 14)- (19), can be used. Still, the most meaningful sets of equations are ( 14)-( 17) and ( 14), ( 15), (18), and (19). The first enables control over average active or average reactive power production and enables the complete elimination of active power oscillations.…”
Section: Power and Current Production Maximization And Management Schemementioning
confidence: 99%
See 1 more Smart Citation
“…Reference [11] discussed different control parameters that were used to estimate the grid impedance, while reference [10] estimated the system parameters for balancing the system. Many methods were used for unbalanced current compensation or reduction, and these are discussed in [16][17][18][19], and different control cases under unbalanced load are discussed in [20,21].…”
Section: Introductionmentioning
confidence: 99%