2006
DOI: 10.1007/s10549-006-9305-x
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasound-guided vacuum-assisted core breast biopsy: experience with 406 cases

Abstract: US-guided VABB is an accurate and safe procedure. The main indication is the non-palpable suspicious breast lesions (category 4). This new technique could be a good alternative for percutaneous and surgery biopsy.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

5
53
2
3

Year Published

2009
2009
2018
2018

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 83 publications
(63 citation statements)
references
References 22 publications
(53 reference statements)
5
53
2
3
Order By: Relevance
“…Under ultrasound guidance, the DCIS underestimation rates were 39-67% for 14-gauge ACNB and 17-41% for VAB [3,17,[20][21][22][23]. Our ultrasound-guided ACNB DCIS underestimation rate (47.8%) was compatible with the ultrasound-guided ACNB underestimation rates in previous reports, but was higher than the STguided rates.…”
Section: Discussionsupporting
confidence: 85%
See 1 more Smart Citation
“…Under ultrasound guidance, the DCIS underestimation rates were 39-67% for 14-gauge ACNB and 17-41% for VAB [3,17,[20][21][22][23]. Our ultrasound-guided ACNB DCIS underestimation rate (47.8%) was compatible with the ultrasound-guided ACNB underestimation rates in previous reports, but was higher than the STguided rates.…”
Section: Discussionsupporting
confidence: 85%
“…Selection of biopsy device among ACNB or VAB under ultrasound guidance was dependent on the lesion factors and clinical factors as follows. Generally, ultrasound-guided 14-gauge ACNB is initially performed to biopsy sonographically visible breast masses regardless of the palpability of the lesion [12,[19][20]. However, VAB was preferred for lesions in which there were potential benefits from using the device [8,21], including lesions with heterogeneous characteristics, intraductal lesions and microcalcification visible in ultrasound.…”
Section: Biopsy Proceduresmentioning
confidence: 99%
“…There is also a good argument for advocating the use of VAB for selected cases in BI-RADS Category 4, particularly 4a, which is associated with a low but significant risk of malignancy in the range of 2-10%, as VAB has been demonstrated to have a very high negative predictive rate (99%) 8 .…”
Section: The Changing Role Of Vacuum Assisted Biopsy Of the Breastmentioning
confidence: 99%
“…При core-биопсии опу-холей молочных желез максимально возможной в ис-пользовании является игла G14, в то время как при ВАБ используются зонды (иглы) G8 и G11, обеспечи-вающие более эффективный забор материала, мень-шее число осложнений и лучший косметический ре-зультат [7,8]. Зонды G8, используемые для тотальной вакуумной биопсии новообразований молочных желез или их вакуумной резекции, сочетают удовлетвори-тельную визуализацию в момент удаления и надеж-ность гистологического диагноза по полученному ма-териалу [3, 9,10].…”
unclassified
“…ВАБ -точная и безопасная процедура, чувстви-тельность метода составляет 97 %, специфичность до-стигает 100 %, точность -99 % [7]. Основным показа-нием для диагностического применения метода является биопсия непальпируемых, подозрительных на рак новообразований молочной железы, которые по классификации BI-RADS (Breast Imaging Reporting and Data System) относятся к категории 4 или 5 [6,20], пальпируемым подозрительным образованиям молоч-ных желез и микрокальцинатам [21,22].…”
unclassified