Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2015
DOI: 10.1016/j.sab.2015.03.002
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasound-assisted single-drop microextraction for the determination of cadmium in vegetable oils using high-resolution continuum source electrothermal atomic absorption spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 43 publications
(10 citation statements)
references
References 26 publications
0
10
0
Order By: Relevance
“…In single-drop microextraction (SDme), microliter amounts (from 1 to 8 μL) of an extracting solvent are suspended in a syringe needle and directly immersed in the sample or in the headspace (Pinto and Pedroso 2015). multiresidue determination of pesticides (Dos Anjos and De Andrade 2014), as well as the determination of Cd in vegetable oils (Almeida et al 2015) demonstrated the successful use of SDme for sample preparation, with a diminution of solvent consumption from several mL to few μL.…”
Section: Liquid-phase Microextractionmentioning
confidence: 99%
“…In single-drop microextraction (SDme), microliter amounts (from 1 to 8 μL) of an extracting solvent are suspended in a syringe needle and directly immersed in the sample or in the headspace (Pinto and Pedroso 2015). multiresidue determination of pesticides (Dos Anjos and De Andrade 2014), as well as the determination of Cd in vegetable oils (Almeida et al 2015) demonstrated the successful use of SDme for sample preparation, with a diminution of solvent consumption from several mL to few μL.…”
Section: Liquid-phase Microextractionmentioning
confidence: 99%
“…Almeida et al 121 introduced a UA-SDME method combined with high-resolution continuum source electrothermal atomic absorption spectrometry (HR-CS-ET-AAS). They used a two-level full-factorial design program for optimization of analytical parameters.…”
Section: Single-drop Microextraction (Sdme)mentioning
confidence: 99%
“…An acidic medium was used as extractant for the preconcentration of Cd in vegetable oils by DI-UA-SDME [37]. A reduction in sensitivity was reported when using a medium containing HNO 3 due to the destruction of the pyrolytic surface of graphite furnace…”
Section: Aqueous Solutionsmentioning
confidence: 99%
“…Several reviews focused on HR-CS-GFAAS are available in the literature for interesting readers [145][146][147][148][149].The combination of LPME-HR-CS-GFAAS has been performed in few recent publications. Concretely, they involved the preconcentration of Cd from vegetable oils by UA-SDME [37], Cr from effluents and water sources by DLLME-SFO [67] and Pt from geological samples and spent automobile converter by DSDME [150] prior to HR-CS-GFAAS. HR-CS-GFAAS seems advantageous after LPME preconcentration due to the multielemental capability and spectral correction functions.…”
Section: Advances In Gfaas Instrumentationmentioning
confidence: 99%
See 1 more Smart Citation