Ultrasonic impact treatment of CoCrMo alloy: Surface composition and properties

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
12
0
4

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 37 publications
(16 citation statements)
references
References 33 publications
0
12
0
4
Order By: Relevance
“…Table (4) presented that the fatigue strength of pre-corroded specimens for 77 days in salt solution was (44 MPa) showing (4.5%) decreased and that of pre-corroded specimens of 77 days with prior one line of UP was (45 MPa) showing (2.2%) decreased as compared with the fatigue strength of dry specimens which was (46 MPa). an approximately (60%) decrease in fatigue strength of 7075-T6 Al-alloy was determined by Genel [13] when he used the same conditions of the present work, but the corrosive time was 3 years.…”
Section: Constant Amplitude Fatigue Test Resultsmentioning
confidence: 94%
See 2 more Smart Citations
“…Table (4) presented that the fatigue strength of pre-corroded specimens for 77 days in salt solution was (44 MPa) showing (4.5%) decreased and that of pre-corroded specimens of 77 days with prior one line of UP was (45 MPa) showing (2.2%) decreased as compared with the fatigue strength of dry specimens which was (46 MPa). an approximately (60%) decrease in fatigue strength of 7075-T6 Al-alloy was determined by Genel [13] when he used the same conditions of the present work, but the corrosive time was 3 years.…”
Section: Constant Amplitude Fatigue Test Resultsmentioning
confidence: 94%
“…This energy is applied into the metal by converting the resonant, harmonic oscillation of an acoustically tuned body to mechanical impulses on a surface. The figure (4) shows UP device and figure (5) shows fatigue specimens before and after UP device. The main technical parameters of UP device are given below [11]:…”
Section: Ultrasonic Impact Peening (Uip) Devicementioning
confidence: 99%
See 1 more Smart Citation
“…Нещодавно було показано успішне застосування УЗУО для модифікації структури, хімічного стану та поліпшення механічних і корозійних властивостей біомедичних сплавів Ti-6Al-4V (рис. 2) [15] та Co-Cr-Mo [16,17].…”
unclassified
“…Оксидні покриття на сплавах цирконію широко застосовують у виробництві медичних конструкцій та імплантатів [22]. Тому цілеспрямоване створення оксидних плівок на цирконієвих/титанових/кобальтових сплавах шляхом механохімічного окиснення, ініційованого інтенсивною деформацією при УЗУО [17,20,21], є перспективним, оскільки їх наявність забезпечує високу корозійну стійкість і біохімічну сумісність металевих імплантатів. При розгляді корозійної поведінки металевих матеріалів керуються потенціалом (E corr ) корозії, який є загальновизнаним критерієм оцінки корозійної поведінки.…”
unclassified