2022
DOI: 10.1039/d1an02287c
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasensitive ratiometric fluorescent probes for Hg(ii) and trypsin activity based on carbon dots and metalloporphyrin via a target recycling amplification strategy

Abstract: A convenient and ultrasensitive ratiometric fluorescent probe was innovatively established for Hg(II) detection and trypsin activity evaluation based on carbon dots (CDs) and tetraphenylporphyrin tetrasulfonic acid (TPPS) by using bovine...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 45 publications
0
4
0
Order By: Relevance
“…The aggregation system causes fluorescence quenching, and the entry of Try hydrolyzes Pro and disperses CQDs, which in turn activates the fluorescence production (Figure 13b) [155]. A fluorescent probe involving tetraphenyl porphyrin tetrasulfonic acid (TPPS) with BSA as the substrate achieved an ultra-low-detection limit of 0.013 ng/mL for trypsin [156].…”
Section: Fluorescence Methodsmentioning
confidence: 99%
“…The aggregation system causes fluorescence quenching, and the entry of Try hydrolyzes Pro and disperses CQDs, which in turn activates the fluorescence production (Figure 13b) [155]. A fluorescent probe involving tetraphenyl porphyrin tetrasulfonic acid (TPPS) with BSA as the substrate achieved an ultra-low-detection limit of 0.013 ng/mL for trypsin [156].…”
Section: Fluorescence Methodsmentioning
confidence: 99%
“…The detection and quantification of heavy metal ions in the environment are crucial due to their high toxicity and potential adverse effects on ecosystems and human health. Heavy metal ions, such as mercury (Hg 2+ ) [ 86 , 101 , 108 , 109 , 110 , 111 , 112 , 113 , 114 , 115 ], lead (Pb 2+ ) [ 67 , 98 , 106 , 116 , 117 , 118 , 119 ], chromium (Cr 6+ ) [ 120 , 121 , 122 , 123 ], copper (Cu 2+ ) [ 67 , 79 , 92 , 109 , 119 , 124 , 125 , 126 , 127 , 128 , 129 , 130 ], and silver (Ag + ) [ 78 , 117 , 131 , 132 , 133 ], can contaminate water, soil, and air through various industrial processes and human activities. Table 1 summarizes sensing of some heavy metal ions using CD-based ratiometric fluorescence probes.…”
Section: Application In Environmental Monitoringmentioning
confidence: 99%
“…Human urine samples and human serum samples were all obtained from healthy volunteers in our lab and treated following our reported processes. 29,30 Human urine samples were centrifuged at 10 000 rpm for 15 min and then ltered through a 0.22 mM lter membrane (Merck Millipore, USA). The pretreated human urine samples were diluted 100-fold with Tris-HCl buffer (50 mM, pH 6.0) before detection.…”
Section: Preparation Of Authentic Samplesmentioning
confidence: 99%