UltraMassExplorer: a browser‐based application for the evaluation of high‐resolution mass spectrometric data

Abstract: Rationale: High-resolution mass spectrometry (HRMS) with high sample throughput has become an important analytical tool for the analysis of highly complex samples and data processing has become a major challenge for the user community. Evaluating direct-infusion HRMS data without automated tools for batch processing can be a time-consuming step in the analytical pipeline. Therefore, we developed a new browser-based software tool for processing HRMS data. Methods:The software, named UltraMassExplorer (UME), was… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
59
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 46 publications
(59 citation statements)
references
References 38 publications
(55 reference statements)
0
59
0
Order By: Relevance
“…Molecular compositions were assigned using the open source browser-based application UltraMassExplorer created by Leefmann et al ( http://dockersrv1.awi.de:3838/ume ) ( Leefmann et al, 2019 ). The pivot table with all assigned formulae is presented in Supplementary file Table S5 .…”
Section: Methodsmentioning
confidence: 99%
“…Molecular compositions were assigned using the open source browser-based application UltraMassExplorer created by Leefmann et al ( http://dockersrv1.awi.de:3838/ume ) ( Leefmann et al, 2019 ). The pivot table with all assigned formulae is presented in Supplementary file Table S5 .…”
Section: Methodsmentioning
confidence: 99%
“…As of the publication of this article, community-driven software only covers molecular formula assignment and basic exploration of variance for direct-infusion data. 19,20 To fully exploit the potential of HPLC-HRMS, such tools could be expanded upon to include data analysis routines that isolate systematic variation from HPLC-HRMS datasets.…”
Section: Introductionmentioning
confidence: 99%
“…Where laboratories a and c determined 499 and 213 compositions, respectively, laboratories b, d, and e found significantly fewer of these compositions, lower by a factor of 10. The abundant CHOS compounds could also be originated from impurities, e.g., surfactants [24].…”
Section: Intercomparison Of the Fticr Ms Data For The Srha Samplementioning
confidence: 99%
“…However, the dynamic range and sensitivity are specific features of the instruments and depend mainly on the ion optics, ICR cell geometry, and the homogeneity of the magnetic field [30]. In addition, the lifetime of ions depends drastically on the ion accumulation parameters [24]. The latter were not standardized in this study due to the different architecture of the instruments used by the participating laboratories.…”
Section: General Characteristics Of the Full Data Set On Intercomparimentioning