2017
DOI: 10.1007/s00604-017-2510-y
|View full text |Cite
|
Sign up to set email alerts
|

Ultra-sensitive voltammetric simultaneous determination of dopamine, uric acid and ascorbic acid based on a graphene-coated alumina electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
18
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 40 publications
(19 citation statements)
references
References 33 publications
1
18
0
Order By: Relevance
“…Moreover, the peak potential of the individual detection of AA, DA or UA at Au/CRGO/Fc-ac-PPP shifts to a lower potential range compared to the other electrodes. This behavior proves that the kinetics of electron transfer of these analytes has been faster on the nanocomposite than the other electrodes [32]. In addition, the oxidation peaks are separated well compared to the other electrodes.…”
Section: Electrochemical Activities Of Aa Da and Ua On Modified Surfmentioning
confidence: 52%
“…Moreover, the peak potential of the individual detection of AA, DA or UA at Au/CRGO/Fc-ac-PPP shifts to a lower potential range compared to the other electrodes. This behavior proves that the kinetics of electron transfer of these analytes has been faster on the nanocomposite than the other electrodes [32]. In addition, the oxidation peaks are separated well compared to the other electrodes.…”
Section: Electrochemical Activities Of Aa Da and Ua On Modified Surfmentioning
confidence: 52%
“…Methane of 99.5 vol.% purity (UN 1971, 2.5) and technical nitrogen 99.5 vol.% (UN 1066) have been used in these experiments. The catalyst-free CVD process was performed at atmospheric pressure and temperature of 1000 °C in methane (CH 4 , flow of 50 cm 3 /min) and nitrogen (N 2 , flowing of 500 cm 3 /min) gas stream [ 21 , 22 ]. Time of the reaction was adjusted depending on the desired structure of the coating; for example, mass gain of 15% of the substrate weight was reached during 20 min of processing.…”
Section: Methodsmentioning
confidence: 99%
“…The morphology of carbon−alumina hybrid nanostructures is controlled by the deposition time, ratio between carbon source (methane) and carrier gas (nitrogen), and the flow rate [ 21 , 23 ]. The deposition time of 20 min (mass gain of 15%) corresponding to 3–7 layers of graphene has led to type of scaffold marked here as “C3”), Figure 1 a,c,e, and deposition time of 120 min produced structures decorated with graphene-like flakes or protrusions, scaffold type marked here as “C4” [ 22 ], Figure 1 b,d,f. These images were obtained with TEM (JEOL JEM-2200FS HR-TEM with two C s -correctors, 200 kV field emission gun (FEG) and in-column energy filter (Omega Filter) configured to produce a high-end energy filtered imaging) and SEM (Zeiss HR Gemini FESEM Ultra 55 equipped with Bruker EDX system ESPRIT 1.8 suitable for energy-dispersive X-ray measurements).…”
Section: Methodsmentioning
confidence: 99%
“…As shown in Table 1, this work has advantages over published methods [25,[31][32][33][34][35][36] on sensitivity, linear range, and ease of operation. Although the public method [30] is better than this work in terms of detection limit, this work has a widest linear range from 1.0 × 10 À 9 to 1.0 × 10 MÀ > 3 M.…”
Section: Detection Of Inhibition Of [Ru(bpy )3 ] 2 + /Dbae System By mentioning
confidence: 99%