2022
DOI: 10.1016/j.aca.2022.339634
|View full text |Cite
|
Sign up to set email alerts
|

Ultra-sensitive speciation analysis of tellurium by manganese and iron assisted photochemical vapor generation coupled to ICP-MS/MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
15
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 17 publications
(16 citation statements)
references
References 44 publications
1
15
0
Order By: Relevance
“…Some discrepancy was found for ocean water CRMs ranging 1.1−1.8 ng L −1 Te IV+VI in CASS-5, CASS-6, and NASS-7 (Table 1) compared to previously reported values of 45 ± 6 ng L −1 total tellurium for CASS-5 41 and similar values in previous generations of NASS (46 ± 5 ng L −1 for NASS-4 and 48 ± 5 ng L −1 for NASS-5). Very recently, a value of <LOD of 5.7 ng L −1 total tellurium was reported for CASS-5 and NASS-7, 27 in agreement with low concentrations found in our work.…”
Section: ■ Experimental Sectionsupporting
confidence: 93%
See 2 more Smart Citations
“…Some discrepancy was found for ocean water CRMs ranging 1.1−1.8 ng L −1 Te IV+VI in CASS-5, CASS-6, and NASS-7 (Table 1) compared to previously reported values of 45 ± 6 ng L −1 total tellurium for CASS-5 41 and similar values in previous generations of NASS (46 ± 5 ng L −1 for NASS-4 and 48 ± 5 ng L −1 for NASS-5). Very recently, a value of <LOD of 5.7 ng L −1 total tellurium was reported for CASS-5 and NASS-7, 27 in agreement with low concentrations found in our work.…”
Section: ■ Experimental Sectionsupporting
confidence: 93%
“…Similar O 2 mode conditions were chosen recently for tellurium determination by photochemical vapor generation coupled to ICP−MS/MS. 27 Even if the use of the reaction cell with O 2 improves the background, it leads to significant reduction of the sensitivity. The use of auxiliary gases in the reaction cell, such as He and H 2 , may increase the reaction stability and, therefore, the sensitivity.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
See 1 more Smart Citation
“…Metal sensitizers exhibiting such effects on PVG include: Cd 2+ ions for As 3+ and As 5+ , Se 6+ , and W 6+ ; Co 2+ ions for Bi 3+ , , Cd 2+ , Ge 4+ , Pb 2+ , Sb 3+ , Te 4+ , and Tl + ; Cu 2+ ions for Br – , Cl – , , F – , , Ir 3+ , and Rh 3+ ; Fe 2+ and/or Fe 3+ ions for As 3+ , Bi 3+ , Te 4+ , Mo 6+ , Cd 2+ , and Os 4+ ; Ni 2+ ions for Pb 2+ ; and V 4+ and V 5+ for Te 4+ and Te 6+ . A greater effect (additive or synergistic) was reported for several analytes when a combination of two metal sensitizers was employed: namely, Co 2+ and Cu 2+ ions for Mo 6+ ; Cd 2+ and Co 2+ for Os 4+ , Re 7+ , and Ru 3+ ; , and Mn 2+ and Fe 2+ ions for Te 4+ . The mechanism of the action of the metal sensitizers on PVG remains to be fully elucidated, but the latest studies dealing with application of electron paramagnetic resonance spin trapping techniques support the initial thesis that transition metal ions enhance the yield of highly reducing CO 2 •– during UV irradiation of HCOOH. ,,,, …”
Section: Introductionmentioning
confidence: 99%
“…11,17 In addition, Mn 2+ , recently reported effective for PVG of Te 4+ , was tested. 36 The effects of various concentrations of individual metal ions on PVG of Ir at a sample flow rate of 1.5 mL min −1 are shown in Figure 2.…”
Section: ■ Introductionmentioning
confidence: 99%