2022
DOI: 10.1021/acs.analchem.2c03280
|View full text |Cite
|
Sign up to set email alerts
|

Non-chromatographic Speciation Analysis of Tellurium by HG-ICP–MS/MS at Sub ng L–1 Concentration in Natural Waters Using TiIII as a Pre-Reducing Agent

Abstract: An automated and high-throughput (36 h–1) method for extremely sensitive determination of the two main tellurium species in the environment, namely, tellurite (TeIV) and tellurate (TeVI), was developed. Flow injection hydride generation was interfaced for the first time with inductively coupled plasma triple quadrupole mass spectrometry (ICP–MS/MS) detection to assure interference-free tellurium analysis. ICP–MS/MS conditions were studied in detail. Using a mixture of He + O2 gases in the reaction cell, the ba… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 41 publications
0
2
0
Order By: Relevance
“…The method was successfully validated against the NRCC CRMs SLRS-3 and 4 (river water). In the HG-ICP-MS determination of Te, elimination of 128 Xe and 130 Xe interferences on the most abundant isotopes 128 Te and 130 Te meant 79 that an LOD of 0.07 ng L −1 could be achieved, thereby making the determination of Te in lake, river, bottled and seawaters possible. Results for total Te in six CRMs agreed well with certificate values.…”
Section: Water Analysismentioning
confidence: 99%
“…The method was successfully validated against the NRCC CRMs SLRS-3 and 4 (river water). In the HG-ICP-MS determination of Te, elimination of 128 Xe and 130 Xe interferences on the most abundant isotopes 128 Te and 130 Te meant 79 that an LOD of 0.07 ng L −1 could be achieved, thereby making the determination of Te in lake, river, bottled and seawaters possible. Results for total Te in six CRMs agreed well with certificate values.…”
Section: Water Analysismentioning
confidence: 99%
“…Garcia-Figueroa et al explored the capabilities of ICP-MS/MS to reduce the influence of spectral interferences on the most natural abundant Te isotopes. 122 For this purpose, FI-HG was interfaced to ICP-MS/MS. Most of the paper is devoted to the optimisation of the experimental conditions affecting HG-ICP-MS/MS.…”
Section: Elemental Speciation Analysismentioning
confidence: 99%