“…Here the circular channel with 3bar inlet pressure and heat flux of 10to 115KW/m 2 was maintained. The results are similar to that of journal [4] along with two boiling mechanisms such as Nucleate boiling and convective boiling.Carlo Bartoli et al [60] made use of ultrasonic waves in 2010 to enhance the heat transfer. They selected the sub-cooled boiling regime as it suits well for the heat transfer enhancement.…”
Section: Flow Boiling 41 Experimental Studies On Flow Boilingsupporting
confidence: 83%
See 2 more Smart Citations
“…Here the circular channel with 3bar inlet pressure and heat flux of 10to 115KW/m 2 was maintained. The results are similar to that of journal [4] along with two boiling mechanisms such as Nucleate boiling and convective boiling.Carlo Bartoli et al [60] made use of ultrasonic waves in 2010 to enhance the heat transfer. They selected the sub-cooled boiling regime as it suits well for the heat transfer enhancement.…”
Section: Flow Boiling 41 Experimental Studies On Flow Boilingsupporting
confidence: 83%
“…Boye H et al [34] studied the flow boiling heat transfer characteristics similar to previously discussed journal [4]. Here the circular channel with 3bar inlet pressure and heat flux of 10to 115KW/m 2 was maintained.…”
Section: Flow Boiling 41 Experimental Studies On Flow Boilingmentioning
confidence: 95%
See 1 more Smart Citation
“…Results varied between 0.6 and 1. 8 [Ω], which is within the uncertainty of the individual TSV resistance values (between 0.7 and 2[Ω]).…”
Section: Discussionmentioning
confidence: 89%
“…Indeed, the reliability, performance, and power dissipation of interconnects and transistors are heavily dependent on their operating temperature. Therefore, backside microchannel fluidic cooling concepts, be it single-phase water or two-phase dielectric evaporative cooling using environmentally-friendly refrigerants, were introduced into high-end server products [5][6][7][8].…”
Section: Introductionmentioning