Two‐dimensional antiscatter grid: A novel scatter rejection device for Cone‐beam computed tomography

Abstract: Purpose: Scattered radiation remains to be a major cause of image quality degradation in Flat Panel Detector (FPD)-based Cone-beam computed tomography (CBCT). We have been investigating a novel two-dimensional antiscatter grid (2D-ASG) concept to reduce scatter intensity, and hence improve CBCT image quality. We present the first CBCT imaging experiments performed with the 2D-ASG prototype, and demonstrate its efficacy in improving CBCT image quality. Methods: A 2D-ASG prototype with septa focused to x-ray sou… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
51
1

Year Published

2019
2019
2022
2022

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 22 publications
(53 citation statements)
references
References 14 publications
1
51
1
Order By: Relevance
“…The cadaver heads all had a complete oral cavity, with the mandibula, the maxilla, the palate, soft tissues and some teeth present. As metallic restoration materials cause scattering on CBCT images, and hence reduce soft-tissue visualization by loss of contrast resolution and image artifacts [2], all metallic materials were removed prior to CBCT scanning.…”
Section: Cadaversmentioning
confidence: 99%
“…The cadaver heads all had a complete oral cavity, with the mandibula, the maxilla, the palate, soft tissues and some teeth present. As metallic restoration materials cause scattering on CBCT images, and hence reduce soft-tissue visualization by loss of contrast resolution and image artifacts [2], all metallic materials were removed prior to CBCT scanning.…”
Section: Cadaversmentioning
confidence: 99%
“…In this work, we developed a novel method to reduce ring artifacts in CBCT images acquired with 2DASG prototypes. 2,3 Although the general formulation is presented as the full biharmonic form, in this work, we considered a special case solution by decoupling the "x" and "y" directions in the projections. Artifacts caused by 2DASG septa shadows appear as GLA in projections, and may spread to more than one adjacent pixel row or column.…”
Section: Discussionmentioning
confidence: 99%
“…In this work, we developed a novel method to reduce ring artifacts in CBCT images acquired with 2DASG prototypes . Although the general formulation is presented as the full biharmonic form, in this work, we considered a special case solution by decoupling the “x” and “y” directions in the projections.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations