2011
DOI: 10.1016/j.icheatmasstransfer.2010.11.014
|View full text |Cite
|
Sign up to set email alerts
|

Turbulent heat transfer enhancement in a heat exchanger using helically corrugated tube

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
67
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 225 publications
(68 citation statements)
references
References 18 publications
1
67
0
Order By: Relevance
“…14. Some widely used enhanced tubes in practical applications, such as internally finned tube [22], transversally grooved tube [23], helically corrugated tube [24], discrete corrugated tube [8] and some tube inserts like short-length twisted tape [25], coiled square wires [26] and twisted tape and wire coil turbulators [27] are selected to perform the comparisons. It is evident that the proposed enhanced tube provides considerably higher overall thermal performance than the conventional grooved tubes, finned tube and tube inserts but slightly lower performance than the helically corrugated tube and discrete corrugated tube.…”
Section: Comparison With Previous Workmentioning
confidence: 99%
“…14. Some widely used enhanced tubes in practical applications, such as internally finned tube [22], transversally grooved tube [23], helically corrugated tube [24], discrete corrugated tube [8] and some tube inserts like short-length twisted tape [25], coiled square wires [26] and twisted tape and wire coil turbulators [27] are selected to perform the comparisons. It is evident that the proposed enhanced tube provides considerably higher overall thermal performance than the conventional grooved tubes, finned tube and tube inserts but slightly lower performance than the helically corrugated tube and discrete corrugated tube.…”
Section: Comparison With Previous Workmentioning
confidence: 99%
“…Pethkool et al [4] experimentally studied the heat transfer performance of helically corrugated tube and got the empirical formula. Kareem et al [5] studied the three-start spirally corrugated tube by experiment and simulation, he said that this geometry with a creative spiral corrugation profile can improve the heat transfer significantly with reasonable increase in friction factor.…”
Section: Introductionmentioning
confidence: 99%
“…The literature involving corrugated double pipe heat exchangers is virtually exclusively concerned with experimentation. Representative among these are [20,21].…”
Section: Introductionmentioning