2017
DOI: 10.1049/iet-gtd.2017.0033
|View full text |Cite
|
Sign up to set email alerts
|

Tuned‐TSC based SVC for reactive power compensation and harmonic reduction in unbalanced distribution system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(13 citation statements)
references
References 48 publications
0
11
0
Order By: Relevance
“…Equation (4) shows that both positive-sequence reactive components and negative-sequence components of the three-phase grid side currents are 0 at this time, and only positive-sequence active components are left at the grid side.…”
Section: Relationship Between Power Factor Correction and Imbalance Smentioning
confidence: 99%
See 1 more Smart Citation
“…Equation (4) shows that both positive-sequence reactive components and negative-sequence components of the three-phase grid side currents are 0 at this time, and only positive-sequence active components are left at the grid side.…”
Section: Relationship Between Power Factor Correction and Imbalance Smentioning
confidence: 99%
“…Elements which may be used to make SVC typically include thyristor-controlled reactor (TCR) and thyristor-switched capacitor (TSC). In [4,5], The innovations of this paper can be described as follows: In Section 2, the relationship between power factor correction and load imbalance suppression in three-phase three-wire system is analyzed. In Section 3, the theoretical compensation ability of the D-CAP for negative-sequence current is derived.…”
Section: Introductionmentioning
confidence: 99%
“…Compared with the static var compensator (SVC), which is a dynamic reactive power compensator, the SVG is widely used in improving the power quality due to its advantages, such as fast compensation time and continuous compensation. Therefore, SVG is currently a better way to solve the above-mentioned client power quality problem [8][9][10] . In Ref.…”
Section: Introductionmentioning
confidence: 99%
“…In Das et al, the authors introduced the use of two SVCs, one with Y configuration and the other with Δ configuration, to perform three functions: balancing a three‐phase load in four wire system, compensating the neutral current, and correcting power factor with harmonic minimization. Furthermore, the optimum firing angles for the TCRs were determined on the basis of harmonic minimization.…”
Section: Introductionmentioning
confidence: 99%