A novel soft-start method for SVG based on D-axis orientation

Abstract: In this paper, a novel method for shock-free soft-start is proposed. The novel method can realize the aim of no-overshoot and inrush of current during the entire soft-start process, thus the start process is safe, stable, and reliable. When the uncontrolled rectification stage ends, a sinusoidal signal synchronized with the grid voltage is generated through dq coordinate transformation and D-axis orientation, then the signal is transmitted to the three-phase inverter bridge. The AC voltage output of the invert… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 12 publications
0
1
0
Order By: Relevance
“…If the rotor current exceeds the set value during a fault, the crowbar circuit is used to shortcircuit the rotor winding and converter. [4][5] Consuming power on the current limiting resistor to reduce the fault current on the rotor side by selecting a suitable current limiting resistor with a suitable resistance value, the voltage borne by the converter switch tube is kept within a safe range. At the same time, the pitch angle is adjusted to reduce the fan speed to prevent overspeed shutdown, so that all parts of the doubly fed fan are not damaged during the fault period and maintain grid connection operation until the fault is removed or the time required for low-voltage crossing is reached before grid disconnection.…”
Section: Introductionmentioning
confidence: 99%
“…If the rotor current exceeds the set value during a fault, the crowbar circuit is used to shortcircuit the rotor winding and converter. [4][5] Consuming power on the current limiting resistor to reduce the fault current on the rotor side by selecting a suitable current limiting resistor with a suitable resistance value, the voltage borne by the converter switch tube is kept within a safe range. At the same time, the pitch angle is adjusted to reduce the fan speed to prevent overspeed shutdown, so that all parts of the doubly fed fan are not damaged during the fault period and maintain grid connection operation until the fault is removed or the time required for low-voltage crossing is reached before grid disconnection.…”
Section: Introductionmentioning
confidence: 99%
“…Different methods for commissioning microgrid inverters have been proposed in the literature, such as soft-start, soft-commissioning, and black start [43], [44], [96], [97], [98], [99]. However, special control methods are needed after synchronization to commission the inverters in islanded microgrids.…”