2007
DOI: 10.1016/j.radonc.2007.01.014
|View full text |Cite
|
Sign up to set email alerts
|

Tumour and target volumes in permanent prostate brachytherapy: A supplement to the ESTRO/EAU/EORTC recommendations on prostate brachytherapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
156
0
5

Year Published

2008
2008
2022
2022

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 243 publications
(163 citation statements)
references
References 81 publications
2
156
0
5
Order By: Relevance
“…A more standard approach to volume delineation should be an important aspect of quality assurance in prostate BT. 17 As stated by Morris et al 10 in their study, "dose metrics are not equivalent to oncologic end points and must be calibrated against disease-free survival using biochemical and clinical end points for each institution".…”
Section: Discussionmentioning
confidence: 99%
“…A more standard approach to volume delineation should be an important aspect of quality assurance in prostate BT. 17 As stated by Morris et al 10 in their study, "dose metrics are not equivalent to oncologic end points and must be calibrated against disease-free survival using biochemical and clinical end points for each institution".…”
Section: Discussionmentioning
confidence: 99%
“…Radioactive seeds were included inside the phantom's prostate to simulate the assessment of the seed positioning during a clinical prostate brachytherapy treatment [1,13].…”
Section: Imaging a Prostate Brachytherapy Treatmentmentioning
confidence: 99%
“…The maximum absorbed dose in the urethra was below the threshold doses of the value D 10 < 150% and D 30 < 130% of the prescription dose with both seeds. The D 2cc doses in the rectum were significantly lower than the threshold dose limit 145 Gy (24) . The doses in the most irradiated volumes of the rectum, starting from D 0.5cc , as well as in the bladder starting from D 7cc , are higher with the Pd-103 seeds than with I-125 seeds.…”
Section: Discussionmentioning
confidence: 75%
“…Figure 2 shows two sections of such a model. The seeds were positioned according to the modified uniform distribution proposed by Butler et al (24) , as shown on Figure 3. In total, 148 seeds were positioned in 24 applications, forming parallel lined-up segments in tangential direction to the pubic bones, on a spacing grid between segments of 1 cm, maintaining the seed spacing on a single segment of 6 mm between the centers of consecutive seeds.…”
Section: Methodsmentioning
confidence: 99%