2012
DOI: 10.1590/s0100-39842012000500007
|View full text |Cite
|
Sign up to set email alerts
|

Dosimetria comparativa de braquiterapia de próstata com sementes de I-125 e Pd-103 via SISCODES/MCNP

Abstract: Objective: The present paper is aimed at presenting a comparative dosimetric study of prostate brachytherapy with I-125 and Pd-103 seeds. Materials and Methods: A protocol for both implants with 148 seeds was simulated on a heterogeneous three-dimensional pelvic phantom by means of the SISCODES/MCNP5 codes. Dose-volume histograms on prostate, rectum and bladder, dose indexes D 10 , D 30 , D 90 , D 0.5cc , D 2cc and D 7cc , and representations of the spatial dose distribution were evaluated. Results: For a D 90… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0
3

Year Published

2013
2013
2020
2020

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 13 publications
0
4
0
3
Order By: Relevance
“…Além disto é colocada uma sonda vesical no paciente para preencher a bexiga com líquido (soro fisiológico) para facilitar a visualização da próstata na imagem ultrassonográfica. Com a sonda colocada, o agulhamento é feito simetricamente, uma por vez por toda a extensão da próstata, após a colocação das agulhas o "template' é fixado no períneo com pontos de sutura, em seguida é retirado radiografias da pelve em ântero-posterior e perfil [11,12].…”
Section: Discussionunclassified
See 2 more Smart Citations
“…Além disto é colocada uma sonda vesical no paciente para preencher a bexiga com líquido (soro fisiológico) para facilitar a visualização da próstata na imagem ultrassonográfica. Com a sonda colocada, o agulhamento é feito simetricamente, uma por vez por toda a extensão da próstata, após a colocação das agulhas o "template' é fixado no períneo com pontos de sutura, em seguida é retirado radiografias da pelve em ântero-posterior e perfil [11,12].…”
Section: Discussionunclassified
“…Com tudo pronto as agulhas são conectadas ao equipamento de braquiterapia e assim aplicado as sementes [11,12].…”
Section: Discussionunclassified
See 1 more Smart Citation
“…The computer simulations were performed with the MCNP5 code, utilizing a human head voxel phantom (10) , built in the SISCODES program (11,12) . In such a phantom, a hypothetical GBM was inserted, with dissemination in three regions which, in the present study, will be referred to as target tumor, infiltration 1 (I 1 ) and infiltration 2 (I 2 ).…”
Section: Methodsmentioning
confidence: 99%
“…[8] SISCODES code converted this set of images into a voxelized tissue model. [9][10][11][12] The chemical composition and mass density were previously digitalized into SISCODES database. Also, the nuclear data, from ICRU-46, was introduced in the data bank [13].…”
Section: Heart Model For Perfusion Imagementioning
confidence: 99%