Tribology studies of the natural knee using an animal model in a new whole joint natural knee simulator

Abstract: The successful development of early-stage cartilage and meniscus repair interventions in the knee requires biomechanical and biotribological understanding of the design of the therapeutic interventions and their tribological function in the natural joint. The aim of this study was to develop and validate a porcine knee model using a whole joint knee simulator for investigation of the tribological function and biomechanical properties of the natural knee, which could then be used to pre-clinically assess the tr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
28
0
2

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 24 publications
(31 citation statements)
references
References 25 publications
(8 reference statements)
1
28
0
2
Order By: Relevance
“…Therefore, the Authors who considered 0.3-0.4 slideroll ratio were correct with regard to beginning of the squat motion, but not with respect to the complete cycle. Above 30 degrees of flexion, as sliding prevails, wear starts developing between the surfaces due to the shear stress which is caused by the increasing slide 22 . Since the kinematic condition of the TKR geometries is different, wear must differ during the progression of the motion as well, which can be apparently observed on Figure 5.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, the Authors who considered 0.3-0.4 slideroll ratio were correct with regard to beginning of the squat motion, but not with respect to the complete cycle. Above 30 degrees of flexion, as sliding prevails, wear starts developing between the surfaces due to the shear stress which is caused by the increasing slide 22 . Since the kinematic condition of the TKR geometries is different, wear must differ during the progression of the motion as well, which can be apparently observed on Figure 5.…”
Section: Discussionmentioning
confidence: 99%
“…One cycle in squat is defined between 0 to 120 degrees of flexion and extension while the complete range where the propagation of wear monitored is 15 years. A usual knee wear simulation period is 3.5 million cycles 22,23 however squat and deep squat is less frequently exercised in everyday life. If 3.5 million cycles were completed in 15 years, it would be 640 complete deep squat cycles carried out per day.…”
Section: ! !mentioning
confidence: 99%
“…The proximal femur and distal tibia were cleaned of soft tissues to enable placement of the femur and tibia into cement pots (Fig 1). The knee was cemented using polymethylmethacrylate (PMMA; WHWPlastics, UK) and mounted to the knee simulator for investigation according to our previous study [6]. Throughout the procedure, the soft tissues were kept moist using Ringer's solution (Sigma-Aldrich, Buchs, Switzerland).…”
Section: Human Knee Jointmentioning
confidence: 99%
“…Throughout the procedure, the soft tissues were kept moist using Ringer's solution (Sigma-Aldrich, Buchs, Switzerland). The axial force axis was shifted medially by 0.07 of the tibial width by sliding the tibial pot in the fixture with the aim of causing greater medial compartment loading [6].…”
Section: Human Knee Jointmentioning
confidence: 99%
“…Aiqin Liu ve ark [58]. tarafından "doğal diz için deneysel bir eklem simülasyon sistemi" geliştirilmiştir.…”