2021
DOI: 10.1016/j.mtcomm.2020.101892
|View full text |Cite
|
Sign up to set email alerts
|

Tribological and corrosion Behavior of Duplex Coated AISI 316L using plasma based ion implantation and deposItion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
1
1

Year Published

2021
2021
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(10 citation statements)
references
References 34 publications
0
4
1
1
Order By: Relevance
“…The coefficient of friction (COF) for the 350 °C PIII + WC:C sample was 0.08, whereas for the 400 °C PIII + WC:C and 450 °C samples it was 0.15 (COF results shown in Figure 16). The COF results were lower than those reported by Laura et al, Boromei or Fuentes et al [10,41,42], where coatings of plasma nitriding and TiTiN or LTC/a-C:H were both measured to have values larger than 0.6 and a CrCN PVD was measured at 0.2. For a DLC with plasma pretreatment, COF values between 0.12 and 0.59 were obtained in the study by Tillman et al [30] The data for the volume loss in the wear tracks are shown in Table 9.…”
Section: Friction and Wear Test Of Duplex Samplescontrasting
confidence: 72%
“…The coefficient of friction (COF) for the 350 °C PIII + WC:C sample was 0.08, whereas for the 400 °C PIII + WC:C and 450 °C samples it was 0.15 (COF results shown in Figure 16). The COF results were lower than those reported by Laura et al, Boromei or Fuentes et al [10,41,42], where coatings of plasma nitriding and TiTiN or LTC/a-C:H were both measured to have values larger than 0.6 and a CrCN PVD was measured at 0.2. For a DLC with plasma pretreatment, COF values between 0.12 and 0.59 were obtained in the study by Tillman et al [30] The data for the volume loss in the wear tracks are shown in Table 9.…”
Section: Friction and Wear Test Of Duplex Samplescontrasting
confidence: 72%
“…Según la apariencia de la capa, el DLC es más fino pero compacto y homogéneo. En cambio, el TiSiCN es más grueso y de espesor constante, presentando un crecimiento columnar que es típico de los recubrimientos obtenidos mediante técnicas PVD [19].…”
Section: Resultados Y Discusiónunclassified
“…These metal-based substrates can be steel, stainless steel, or many others (such as Mg, Ti, or Ni). [23][24][25][26][27][28] However, many studies used iron-based substrates owing to their typical industrial applications. A notable feature of ceramic coatings is their significantly more noble electrochemical character than metals.…”