2019
DOI: 10.1007/s11547-019-01037-5
|View full text |Cite
|
Sign up to set email alerts
|

Trends in radiation dose and image quality for pediatric patients with a multidetector CT and a third-generation dual-source dual-energy CT

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
18
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 25 publications
(20 citation statements)
references
References 25 publications
2
18
0
Order By: Relevance
“…Concluding, a compromise including preserved image sharpness within lung parenchyma, with minimally blurred mediastinal structures in the face of a median dose reduction of more than 90% may be acceptable when performing serial CT controls in severely ill young patients [26].…”
Section: Discussionmentioning
confidence: 99%
“…Concluding, a compromise including preserved image sharpness within lung parenchyma, with minimally blurred mediastinal structures in the face of a median dose reduction of more than 90% may be acceptable when performing serial CT controls in severely ill young patients [26].…”
Section: Discussionmentioning
confidence: 99%
“…13 While the proven value of spectral CT is continuously rising, 14 there are only a few studies focused on spectral CT applications for pediatric imaging. 9,15,16 For this unique population, imaging applications concentrated on a different domain of clinical questions compared to those of adult patients is of interest. In addition, research of different technical aspects that are related to image quality are of importance, specifically, with respect to the smaller sizes of pediatric patients, and, perhaps more importantly, their sensitivity to ionizing radiation and the obligation to use lower doses.…”
Section: Introductionmentioning
confidence: 99%
“…While the proven value of spectral CT is continuously rising, 14 there are only a few studies focused on spectral CT applications for pediatric imaging 9,15,16 . For this unique population, imaging applications concentrated on a different domain of clinical questions compared to those of adult patients is of interest.…”
Section: Introductionmentioning
confidence: 99%
“…Iodine specific maps allow to quantify iodine uptake in each voxel in order to detect even a little enhancement in a lesion, parenchyma or in the wall of hollow organs (15)(16)(17)(18)(19). Thanks to the new algorithms VNC images have a contrast to noise ratio (CNR) and Hounsfield Unit (HU) accuracy similar to true non-contrast (TNC) ones; in this way, a true scan before administration of contrast medium can be avoided, reducing the radiation dose to the patient (7,20,21). These tools have been investigated in different fields, improving diagnostic possibilities (22,23).…”
Section: Introductionmentioning
confidence: 99%