2020
DOI: 10.1080/2000656x.2020.1856674
|View full text |Cite
|
Sign up to set email alerts
|

Treatment of unstable scaphoid waist nonunion with cancellous bone grafts and cannulated screw or Kirschner wire fixation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
28
1

Year Published

2022
2022
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(29 citation statements)
references
References 30 publications
0
28
1
Order By: Relevance
“…A total of 78 studies met the inclusion criteria and are listed in detail in Supplementary Table i. 8-10,12,13,15-86 The year of publication ranged from 1988 to 2021. There was a total of 7,671 patients included across all studies.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…A total of 78 studies met the inclusion criteria and are listed in detail in Supplementary Table i. 8-10,12,13,15-86 The year of publication ranged from 1988 to 2021. There was a total of 7,671 patients included across all studies.…”
Section: Resultsmentioning
confidence: 99%
“…Due to the likely overlap of patients undergoing fixation using a Herbert screw reported by two studies found in the search, 12,13 only nonunions fixed with Kirschner (K)-wires were included from one retrospective observational study. 12…”
Section: Methodsmentioning
confidence: 99%
“…The use of multiple K-wires for treatment of the scaphoid nonunion is common, due to its superiority in bony union. In a most recent study by Hegazy et al [ 15 ], three convergent 1.1-mm K-wires were placed in retrograde manner for stabilizing scaphoid fracture nonunion, and the union rate was 98% in the K-wire group vs 89% in the Herbert screw group, as well as the shorter union time (12 vs 15 weeks). Chen et al [ 16 ] used divergent K-wires to stabilize the reduced scaphoid fragments in 26 patients with scaphoid nonunion, and the 3 to 6-year follow-up assessments showed the 100% union rate within postoperative 4 months and the good or excellent functional outcomes in all patients.…”
Section: Discussionmentioning
confidence: 99%
“…It should be noted that, use of multiple K-wires alone may not adequately resist the bending forces when fingers are moving to generate the axial compression force at the fracture site. This can partially explain why the long immobilization period was needed in some studies [ 15 , 16 ]. On the other hand, relative to K-wires, a single cannulated screw has superiority in resisting bending force, but may not adequately withstand cyclical rotation or multi-axis loading [ 18 , 20 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation