Tendon function involves the development of an organized hierarchy of collagen fibrils. Small leucine-rich proteoglycans have been implicated in the regulation of fibrillogenesis and decorin is the prototypic member of this family. Decorin-deficient mice demonstrate altered fibril structure and mechanical function in mature skin and tail tendons. However, the developmental role(s) of decorin needs to be elucidated. To define these role(s) during tendon development, tendons (flexor digitorum longus) were analyzed ultrastructurally from postnatal day 10 to 90. Decorin-deficient tendons developed abnormal, irregularly contoured fibrils. Finite mixture modeling estimated that the mature tendon was a three-subpopulation mixture of fibrils with characteristic diameter ranges. During development, in each subpopulation the mean diameter was consistently larger in mutant mice. Also, diameter distributions and the percentage of fibrils in each subpopulation were altered. Biomechanical analyses demonstrated that mature decorin-deficient tendons had significantly reduced strength and stiffness; however, there was no reduction in immature tendons. Expression of decorin and biglycan, a closely related family member, was analyzed during development. Decorin increased with development while biglycan decreased. Spatially, both had a comparable localization throughout the tendon. Biglycan expression increased substantially in decorin-deficient tendons suggesting a potential functional compensation. The accumulation of structural defects during fibril growth, a period associated with decorin expression and low biglycan expression, may be the cause of compromised mechanical function in the absence of decorin. Our findings indicate that decorin is a key regulatory molecule and that the temporal switch from biglycan to decorin is an important event in the coordinate regulation of fibrillogenesis and tendon development.
Iliopsoas abscess is a rare condition with a varied symptomology and aetiology. Patients with this condition often present in different ways to different specialities leading to delays in diagnosis and management. Recent advances in the radiological diagnosis of this traditionally rare abscess have highlighted that there is a lack of evidence relating to its aetiology, symptomology, investigation and management. This article reviews the currently available literature to present a concise and systematic review of iliopsoas abscess.
Evaluations of tendon mechanical behavior based on biochemical and structural arrangement have implications for designing tendon specific treatment modalities or replacement strategies. In addition to the well studied type I collagen, other important constituents of tendon are the small proteoglycans (PGs). PGs have been shown to vary in concentration within differently loaded areas of tendon, implicating them in specific tendon function. This study measured the mechanical properties of multiple tendon tissues from normal mice and from mice with knock-outs of the PGs decorin or biglycan. Tail tendon fascicles, patellar tendons (PT), and flexor digitorum longus tendons (FDL), three tissues representing different in vivo loading environments, were characterized from the three groups of mice. It was hypothesized that the absence of decorin or biglycan would have individual effects on each type of tendon tissue. Surprisingly, no change in mechanical properties was observed for the tail tendon fascicles due to the PG knockouts. The loss of decorin affected the PT causing an increase in modulus and stress relaxation, but had little effect on the FDL. Conversely, the loss of biglycan did not significantly affect the PT, but caused a reduction in both the maximum stress and modulus of the FDL. These results give mechanical support to previous biochemical data that tendons likely are uniquely tailored to their specific location and function. Variances such as those presented here need to be further characterized and taken into account when designing therapies or replacements for any one particular tendon.
Tendons have complex mechanical behaviors that are viscoelastic, nonlinear, and anisotropic. It is widely held that these behaviors are provided for by the tissue's composition and structure. However, little data are available to quantify such structure-function relationships. This study quantified tendon mechanical behaviors, including viscoelasticity and nonlinearity, for groups of mice that were genetically engineered for altered extracellular matrix proteins. Uniaxial tensile stress-relaxation experiments were performed on tail tendon fascicles from the following groups: eight week old decorin knockout, eight week old reduced type I collagen, three week old control, and eight week old control. Data were fit using Fung's quasilinear viscoelastic model, where the model parameters represent the linear viscoelastic and nonlinear elastic response. The viscoelastic properties demonstrated a larger and faster stress relaxation for the decorin knockout and a smaller and slower stress relaxation for the three week control. The elastic parameter, A, in the eight week control group was significantly greater than in the collagen reduction and three week control groups. This study provides quantitative evidence for structure-function relationships in tendon, including the role of proteoglycan in viscoelasticity. Future studies should directly correlate composition and structure with tendon mechanics for the design and evaluation of tissue-engineered constructs or tendon repairs.
Tendons have complex mechanical behaviors that are nonlinear and time dependent. It is widely held that these behaviors are provided by the tissue composition and structure. It is generally thought that type I collagen provides the primary elastic strength to tendon while proteoglycans, such as decorin, play a role in failure and viscoelastic properties. This study sought to quantify such structure-function relationships by comparing tendon mechanical properties between normal mice and mice genetically engineered for altered type I collagen content and absence of decorin. Uniaxial tensile ramp to failure experiments were performed on tail tendon fascicles at two strain rates, 0.5%/s and 50%/s. Mutations in type I collagen led to reduced failure load and stiffness with no changes in failure stress, modulus or strain rate sensitivity. Fascicles without decorin had similar elastic properties to normal fascicles, but reduced strain rate sensitivity. Fascicles from immature mice, with increased decorin content compared to adult fascicles, had inferior elastic properties but higher strain rate sensitivity. These results showed that tendon viscoelasticity is affected by decorin content but not by collagen alterations. This study provides quantitative evidence for structure-function relationships in tendon, including the role of proteoglycan in viscoelasticity.
Aims The primary aim of this study was to assess the independent association of the coronavirus disease 2019 (COVID-19) on postoperative mortality for patients undergoing orthopaedic and trauma surgery. The secondary aim was to identify factors that were associated with developing COVID-19 during the postoperative period. Methods A multicentre retrospective study was conducted of all patients presenting to nine centres over a 50-day period during the COVID-19 pandemic (1 March 2020 to 19 April 2020) with a minimum of 50 days follow-up. Patient demographics, American Society of Anesthesiologists (ASA) grade, priority (urgent or elective), procedure type, COVID-19 status, and postoperative mortality were recorded. Results During the study period, 1,659 procedures were performed in 1,569 patients. There were 68 (4.3%) patients who were diagnosed with COVID-19. There were 85 (5.4%) deaths postoperatively. Patients who had COVID-19 had a significantly lower survival rate when compared with those without a proven SARS-CoV-2 infection (67.6% vs 95.8%, p < 0.001). When adjusting for confounding variables (older age (p < 0.001), female sex (p = 0.004), hip fracture (p = 0.003), and increasing ASA grade (p < 0.001)) a diagnosis of COVID-19 was associated with an increased mortality risk (hazard ratio 1.89, 95% confidence interval (CI) 1.14 to 3.12; p = 0.014). A total of 62 patients developed COVID-19 postoperatively, of which two were in the elective and 60 were in the urgent group. Patients aged > 77 years (odds ratio (OR) 3.16; p = 0.001), with increasing ASA grade (OR 2.74; p < 0.001), sustaining a hip (OR 4.56; p = 0.008) or periprosthetic fracture (OR 14.70; p < 0.001) were more likely to develop COVID-19 postoperatively. Conclusion Perioperative COVID-19 nearly doubled the background postoperative mortality risk following surgery. Patients at risk of developing COVID-19 postoperatively (patients > 77 years, increasing morbidity, sustaining a hip or periprosthetic fracture) may benefit from perioperative shielding.
Heart valve replacements composed of living tissue that can adapt, repair, and grow with a patient would provide a more clinically beneficial option than current inert replacements. Bioartificial valves were produced by entrapping human dermal fibroblasts within a fibrin gel. Using a mold design that presents appropriate mechanical constraints to the cell-induced fibrin gel compaction, gross fiber alignment (commissure-to-commissure alignment in the leaflets and circumferential alignment in the root) and the basic geometry of a native aortic valve were obtained. After static incubation on the mold in complete medium supplemented with transforming growth factor beta 1, insulin, and ascorbate, collagen fibers produced by the entrapped cells were found to coalign with the fibrin based on histological analyses. The resultant tensile mechanical properties were anisotropic. Ultimate tensile strength and tensile modulus of the leaflets in the commissural direction were 0.53 and 2.34 MPa, respectively. The constructs were capable of withstanding backpressure commensurate with porcine aortic valves in regurgitation tests (330 mmHg) and opened and closed under physiological pressure swings of 10 and 20 mmHg, respectively. These data support proof of principle of using cell-remodeled fibrin gel to produce tissue-engineered valve replacements.
Proper replacement or repair of damaged tendons or ligaments requires functionally engineered tissue that mimics their native mechanical properties. While tendon structure-function relationships are generally assumed, there exists little quantitative evidence of the roles of distinct tendon components in tendon function. Previous work has used linear correlations to assess the independent, univariate effects of one structural or one biochemical variable on mechanics. The current study's objective was to simultaneously and rigorously evaluate the relative contributions of seven different structural and compositional variables in predicting tissue mechanical properties through the use of multiple regression statistical models. Structural, biochemical, and mechanical analysis were all performed on tail tendon fascicles from different groups of transgenic mice, which provide a reproducible, noninvasive, in vivo model of changes in tendon structure and composition. Interestingly, glycosaminoglycan (GAG) content was observed to be the strongest predictor of mechanical properties. GAG content was also well correlated with collagen content and mean collagen fibril diameter. Collagen fibril area fraction was a significant predictor only of material properties. Therefore, in a large multivariate model, GAG content was the largest predictor of mechanical properties, perhaps both through direct influence and indirectly through its correlation with collagen content and fibril structure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.