2003
DOI: 10.1109/ted.2003.816109
|View full text |Cite
|
Sign up to set email alerts
|

Traveling-wave tube cold-test circuit optimization using cst MICROWAVE STUDIO

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2007
2007
2019
2019

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(7 citation statements)
references
References 2 publications
0
7
0
Order By: Relevance
“…The slotted cavity length L is dominantly determined by the corresponding k z (the axial propagation constant of the cutoff frequency), and in our design L ¼ 31 mm. The loaded quality factor Q L can be obtained by the passive wave equation and boundary conditions of the slotted structure in the above peniotron model, 18 and here the Q L of the peniotron is shown in Table I. The starting current is the minimum beam current required to start oscillations from noise in the RF structure.…”
Section: Small Signal Calculationmentioning
confidence: 99%
“…The slotted cavity length L is dominantly determined by the corresponding k z (the axial propagation constant of the cutoff frequency), and in our design L ¼ 31 mm. The loaded quality factor Q L can be obtained by the passive wave equation and boundary conditions of the slotted structure in the above peniotron model, 18 and here the Q L of the peniotron is shown in Table I. The starting current is the minimum beam current required to start oscillations from noise in the RF structure.…”
Section: Small Signal Calculationmentioning
confidence: 99%
“…A few successful studies on the use of Microwave Studio simulation software have been conducted. 12,[18][19][20] There is no need for calculations of complex equations or applying the trial and error method to a cavity to achieve effective results, unlike in the studies of Metaxas 17 and Sangdao et al 21 Although the Microwave Studio simulation software can make nearly precise predictions for cavity design, a good knowledge of electromagnetic filed distribution is necessary. The range of the length and diameter aspect ratio of the cylindrical cavity for the simulation trial was 0.5-2.…”
Section: Resonant Cavity Designmentioning
confidence: 99%
“…This module is a general purpose module of the 3D EM simulator and is used for obtaining the broadband frequency domain results like S-parameters. 14,15 The applicator in the form of a rectangular waveguide was designed with an appropriate location of the sample holder for holding specific geometry of the preform. Designing the waveguide with the simulation software offers the benefits of savings of time and price for experiments.…”
Section: High Frequency Em Simulation Softwarementioning
confidence: 99%