2019
DOI: 10.1016/j.snb.2019.05.043
|View full text |Cite
|
Sign up to set email alerts
|

Transistor-based immunosensing in human serum samples without on-site calibration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
8
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 34 publications
0
8
0
Order By: Relevance
“…A substantial amount of work has been devoted to pushing the detection limits and sensitivities of biosensors, but little attention has been paid to sensor calibration and validation in real samples. , Only a few calibration-free biosensing approaches ,, have been developed to increase the adaptation and clinical utility of ECBs. For example, Tarasov and co-workers realized an on-site calibration-free biosensor by using “differential” readout of pairs of differently functionalized, antibody-modified electrolyte-gated field-effect transistors . However, the signal transduction mechanism of this sensor depends on the specific chemical reactivity of their target; thus, this strategy is not generalizable to the measurement of other molecules.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…A substantial amount of work has been devoted to pushing the detection limits and sensitivities of biosensors, but little attention has been paid to sensor calibration and validation in real samples. , Only a few calibration-free biosensing approaches ,, have been developed to increase the adaptation and clinical utility of ECBs. For example, Tarasov and co-workers realized an on-site calibration-free biosensor by using “differential” readout of pairs of differently functionalized, antibody-modified electrolyte-gated field-effect transistors . However, the signal transduction mechanism of this sensor depends on the specific chemical reactivity of their target; thus, this strategy is not generalizable to the measurement of other molecules.…”
mentioning
confidence: 99%
“…For example, Tarasov and co-workers realized an on-site calibration-free biosensor by using "differential" readout of pairs of differently functionalized, antibody-modified electrolyte-gated field-effect transistors. 14 However, the signal transduction mechanism of this sensor depends on the specific chemical reactivity of their target; thus, this strategy is not generalizable to the measurement of other molecules.…”
mentioning
confidence: 99%
“…extended this approach to detect thyroid-stimulating hormone with antibodies in undiluted serum, 17,22 reporting a three-fold improvement in sensitivity after adding large PEG molecules to the electrode surface. Song et al also employed a PEG coating to detect glial fibrillary acidic protein 23 .…”
Section: The Debye Volume: Limiting Screening Through Surface Enginee...mentioning
confidence: 99%
“…17 Without the PEG coating, the nonspecific devices could not detect PSA and the sensitivity of the aptamer-immobilized devices was reduced 5fold. Gutieŕrez-Sanz et al extended this approach to detect thyroid-stimulating hormone with antibodies in undiluted serum, 18,23 reporting a 3-fold improvement in sensitivity after adding large PEG molecules to the electrode surface. Song et al also employed a PEG coating to detect glial fibrillary acidic protein.…”
Section: The Debye Volume: Limiting Screening Through Surface Enginee...mentioning
confidence: 99%