2011
DOI: 10.1002/ccd.23302
|View full text |Cite
|
Sign up to set email alerts
|

Transcatheter closure of large patent ductus arteriosus at high altitude with a novel nitinol device

Abstract: The Nitocclud PDA-R device is safe and effective and can easily close very large PDAs. This device has a high rate of complete occlusion within 1 year and is easily retrieved if embolized.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0
1

Year Published

2012
2012
2018
2018

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 16 publications
(15 citation statements)
references
References 53 publications
(38 reference statements)
0
14
0
1
Order By: Relevance
“…Probably, this type of ducts may be best served with an Amplatzer TM Vascular Plug. In keeping with our findings, a recent PDA study reported a series of 51 high‐altitude patients with large PDAs (mean size 4.6 mm, 25% being larger than 6 mm) who underwent successful catheter closure with Nit‐Occlud ® PDA‐R, demonstrating complete shunt closure rates in all patients at one‐year follow‐up despite high baseline systolic pulmonary artery pressure.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Probably, this type of ducts may be best served with an Amplatzer TM Vascular Plug. In keeping with our findings, a recent PDA study reported a series of 51 high‐altitude patients with large PDAs (mean size 4.6 mm, 25% being larger than 6 mm) who underwent successful catheter closure with Nit‐Occlud ® PDA‐R, demonstrating complete shunt closure rates in all patients at one‐year follow‐up despite high baseline systolic pulmonary artery pressure.…”
Section: Discussionmentioning
confidence: 99%
“…Details of this device have already been described . Briefly, the Nit‐Occlud ® PDA‐R consists of a one‐piece 0.006 inch nitinol wire mesh with very low radial force (9 N, 30% lower than the Amplatzer Duct Occluder), making it less traumatic and superelastic.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Since the first report of transcatheter PDA closure by Porstmann et al there have been huge improvements in this procedure, mainly due to the development of more simple, safe, and effective devices. This has lead operators to attempt closure of larger PDAs in smaller patients …”
Section: Introductionmentioning
confidence: 99%
“…Subsequently a number of other devices were described and these include: botallooccluder [193], buttoned device [194][195][196], clamshell septal umbrella [197], Gianturco coil [198], Duct Occlud pfm [199], detachable (Cook and Flipper) Coils [200][201][202], Gianturco-Grifka vascular occlusion device (GGVOD) [203], polyvinyl alcohol (Ivalon R) foam plug [204], infant buttoned device [205,206], Amplatzer duct occluder [207,208], folding plug buttoned device [209],wireless PDA devices [210,211], reinforced duct-occlude pfm [212], Amplatzer muscular ventricular septal defect occluder [213], Amplatzer vascular plug [214], Nit-Occlud coils [215], Inoue single-branched stent graft [216], non-ferromagnetic Inconel MReye embolization coils [217], Amplatzer vascular plug with prefilled embolization coils [218], self-expanding platinum-coated Nitinol device [219], Chinese self-expandable occluder, similar to the Amplatzer occluder [220], Amplatzer Vascular Plug II [221], Cardio-O-Fix occluder [222], NitOcclud PDA-R (reverse) device [223] and perhaps, others.…”
Section: Patent Ductus Arteriosusmentioning
confidence: 99%