Transabdominal Contrast-Enhanced Ultrasound Imaging of the Prostate

Abstract: Numerous age-related pathologies affect the prostate gland, the most menacing of which is prostate cancer (PCa). The diagnostic tools for prostate investigation are invasive, requiring biopsies when PCa is suspected. Novel dynamic contrast-enhanced ultrasound (DCE-US) imaging approaches have been proposed recently and appear promising for minimally invasive localization of PCa. Ultrasound imaging of the prostate is traditionally performed with a transrectal probe because the location of the prostate allows for… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 28 publications
0
4
0
Order By: Relevance
“…The ultrasound conditions used in this study were chosen to mimic clinical reality as close as possible; that is, a commercial ultrasound scanner was used and operated in its standard contrast imaging mode using a commercially available transducer. The selected transmit frequency of 2.5 MHz is typically used for abdominal CEUS imaging (Mischi et al 2015;Dong et al 2016;Hyvelin et al 2017;de Figueiredo et al 2019;Zhang et al 2020). The acoustic performance of the agents was measured both in vitro and in vivo using a diagnostic ultrasound scanner employed with a convex transducer (EPIQ 7G and C9-2, respectively, Philips Ultrasound Inc., WA, USA).…”
Section: Ultrasound Scannermentioning
confidence: 99%
“…The ultrasound conditions used in this study were chosen to mimic clinical reality as close as possible; that is, a commercial ultrasound scanner was used and operated in its standard contrast imaging mode using a commercially available transducer. The selected transmit frequency of 2.5 MHz is typically used for abdominal CEUS imaging (Mischi et al 2015;Dong et al 2016;Hyvelin et al 2017;de Figueiredo et al 2019;Zhang et al 2020). The acoustic performance of the agents was measured both in vitro and in vivo using a diagnostic ultrasound scanner employed with a convex transducer (EPIQ 7G and C9-2, respectively, Philips Ultrasound Inc., WA, USA).…”
Section: Ultrasound Scannermentioning
confidence: 99%
“…Zonal labeling is considered important for several reasons: tissue characteristics of the PZ and TZ lead to differences in tissue stiffness and UCA flow, causing substantial differences in the selected features [13] , [39] , [41] . Additionally, it is well established that the PZ and TZ provide distinct probabilities for the presence of PCa [42] , [43] .…”
Section: Data Processingmentioning
confidence: 99%
“…We consider however, that in the clini-cal setting of PAE, exquisite detail in the depiction of residual enhancement is not as crucial as in other oncologic applications of CEUS. In another study [10], tr-CEUS and ta-CEUS were utilized to study the prostate before biopsy and to produce time-intensity curves and the results of the two approaches were closely comparable. Since ta-CEUS is less invasive and more comfortable than tr-CEUS, it could partially replace the latter in postinterventional imaging of PAE.…”
Section: Infarcts Ta-ceus Tr-ceusmentioning
confidence: 99%