2013
DOI: 10.1364/oe.21.014466
|View full text |Cite
|
Sign up to set email alerts
|

Traceable terahertz power measurement from 1 THz to 5 THz

Abstract: The metrology institute in Germany, the Physikalisch-Technische Bundesanstalt (PTB), calibrates the spectral responsivity of THz detectors at 2.52 THz traceable to International System of Units. The Terahertz detector calibration facility is equipped with a standard detector calibrated against a cryogenic radiometer at this frequency. In order to extend this service to a broader spectral range in the THz region a new standard detector was developed. This detector is based on a commercial thermopile detector. I… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
24
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
4
3
2

Relationship

1
8

Authors

Journals

citations
Cited by 64 publications
(24 citation statements)
references
References 6 publications
0
24
0
Order By: Relevance
“…The experimental setup for measuring FIR laser power consisted of a continuous wave (CW) laser source, focusing optics and a spatial filter, a reflective optical chopper, a monitor detector, and a THz camera. This facility is described in greater detail elsewhere [10]. The camera and the detectors were mounted upon a platform, the position of which was controlled remotely.…”
Section: Far Infrared Lasermentioning
confidence: 99%
“…The experimental setup for measuring FIR laser power consisted of a continuous wave (CW) laser source, focusing optics and a spatial filter, a reflective optical chopper, a monitor detector, and a THz camera. This facility is described in greater detail elsewhere [10]. The camera and the detectors were mounted upon a platform, the position of which was controlled remotely.…”
Section: Far Infrared Lasermentioning
confidence: 99%
“…4). In combination with the large diameter of 30 mm it is well suited for power measurements of THz radiation as well as for calibration at PTB's worldwide unique THz detector calibration facility [4]. …”
Section: Both Detectors Give Clear Signals When Illuminated Withmentioning
confidence: 99%
“…For a source-based approach, several techniques based on blackbody radiation have been reported [3][4][5][6]; however, these approaches suffer from the presence of unwanted radiation, such as infrared radiation. A second approach that utilizes a detector-based standard has the advantage of precisely measuring absolute power; therefore, several national metrology institutes around the world have focused on the development of the detector-based standard [7][8][9][10][11][12][13]. In this regard, pulse THz power measurements have also been demonstrated with the use of certain types of calibrated detectors [14,15].…”
Section: Introductionmentioning
confidence: 99%