2010
DOI: 10.2116/analsci.26.1007
|View full text |Cite
|
Sign up to set email alerts
|

Traceable Amino Acid Analyses of Proteins and Peptides by Isotope-Dilution Mass Spectrometry Using Precolumn Derivatization Reagent

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 20 publications
(16 citation statements)
references
References 8 publications
(12 reference statements)
0
16
0
Order By: Relevance
“…The measurement was conducted under a selected reaction monitoring (SRM) mode using the following 14. Other conditions were described previously [12]. For HILIC/MS analysis, 2 μL of sample solution was injected into an LC/MS system, LC/MS-2010-EV (Shimadzu, Kyoto, Japan) using a ZIC-HILIC column (2.1 mm ID × 250 mm, Merk Chemicals, Darmstadt, Germany) and equipped with an electrospray ion source.…”
Section: Hydrolysis and Amino Acid Analyses By Pre-column Lc-ms/ Ms Amentioning
confidence: 99%
See 1 more Smart Citation
“…The measurement was conducted under a selected reaction monitoring (SRM) mode using the following 14. Other conditions were described previously [12]. For HILIC/MS analysis, 2 μL of sample solution was injected into an LC/MS system, LC/MS-2010-EV (Shimadzu, Kyoto, Japan) using a ZIC-HILIC column (2.1 mm ID × 250 mm, Merk Chemicals, Darmstadt, Germany) and equipped with an electrospray ion source.…”
Section: Hydrolysis and Amino Acid Analyses By Pre-column Lc-ms/ Ms Amentioning
confidence: 99%
“…For this analysis, hydrophilic chromatography-mass spectrometry (HILIC-MS) was utilized [11]. We have also developed ID MS-based amino acid analysis methods, including precolumn derivatization liquid chromatography-tandem mass spectrometry (LC-MS/MS) [12]. The advantage of this method is that it allows us to quantify hydrophilic amino acids such as glutamic acid and aspartic acid, with a rapid and precise measurement.…”
Section: Introductionmentioning
confidence: 99%
“…3.2). Of among, complete hydrolysis is critical for overall accuracy of the procedure (Albin et al, 2000;Anderson et al, 1977;Darragh et al, 1996;Fountoulakis and Lahm, 1998;Kinumi et al, 2010). Moreover, for the analysis of an unknown protein, optimization of hydrolysis conditions should be considered before conducting the whole procedure.…”
Section: Amino Acid Analysismentioning
confidence: 99%
“…To ensure the reliability of amino acid analyses, the National Metrology Institute of Japan at the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) has developed high-purity certified reference materials (CRMs) for 17 proteinogenic amino acids 1 relevant to clinical chemistry, 2,3 food chemistry, [4][5][6] pharmaceutical biotechnology, 7 and the accurate quantification of protein/peptides [8][9][10] by amino acid analysis. These CRMs will be the primary standards used in the metrological traceability system, and exhibit purities of greater than 0.997 kg kg -1 , with uncertainties of less than 0.003 kg kg -1 .…”
Section: Introductionmentioning
confidence: 99%