2019
DOI: 10.1007/s00216-019-02159-5
|View full text |Cite
|
Sign up to set email alerts
|

Trace-level determination of phosphonates in liquid and solid phase of wastewater and environmental samples by IC-ESI-MS/MS

Abstract: Phosphonates are increasingly used as water-softening agents in detergents, care products, and industrial processes. Despite poor biodegradability, high removal rates during wastewater treatment (WWT) have been observed, owing to strong adsorption affinity to activated sludge and mineral surfaces. Due to phosphonates representing challenging analytes, no method for the compound-specific quantification of phosphonates from solid samples has hitherto been published. In order to improve the data foundation on the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 23 publications
(14 citation statements)
references
References 57 publications
(109 reference statements)
0
13
0
1
Order By: Relevance
“…The background and validation of the sample preparation techniques used for this study have already been presented in detail by Armbruster et al [18] in another publication. In this paragraph, this preparation technique is described briefly.…”
Section: Sample Preparation For Phosphonate Analysismentioning
confidence: 99%
See 3 more Smart Citations
“…The background and validation of the sample preparation techniques used for this study have already been presented in detail by Armbruster et al [18] in another publication. In this paragraph, this preparation technique is described briefly.…”
Section: Sample Preparation For Phosphonate Analysismentioning
confidence: 99%
“…The analysis was carried out via anion exchange chromatography in accordance with Armbruster et al [18]. The method involves a ten-minute washing step with dilute eluent (18 mmol/L sodium hydroxide) immediately after injection for the chromatographic separation of interfering anions with low charge and NTA (present in the extracts of solid samples), followed by a sodium hydroxide gradient with a constant proportion of 20% methanol and detection via ESI-MS/MS.…”
Section: Phosphonate Quantification Via Ic-esi-ms/msmentioning
confidence: 99%
See 2 more Smart Citations
“…For this purpose, a newly developed analytical method based on ion exchange chromatography coupled to tandem mass spectrometry with electrospray ionization (IC-ESI-MS/MS) applying isotope-labeled internal standards was used [13]. This method allows the extraction of >95% phosphonates from solid samples and their quantification down to 0.1 mg/kg on SM and sediment.…”
Section: Introductionmentioning
confidence: 99%